46
TK 56704-1-OP-EN
E
En
ng
giin
ne
e R
RP
PM
M:: Displays the engine speed in RPMs.
D
Diisscch
ha
arrg
ge
e P
Prre
essssu
urre
e:: Displays the unit discharge pressure.
S
Su
uccttiio
on
n P
Prre
essssu
urre
e:: Displays the unit suction pressure.
E
ET
TV
V P
Po
ossiittiio
on
n:: Displays the current position of the ETV valve. ETV units only.
C
Co
om
mp
prre
esssso
orr T
Te
em
mp
pe
erra
attu
urre
e:: Displays the temperature sensed by the
compressor temperature sensor. Scroll compressor only.
II//O
O ((IIn
np
pu
utt//O
Ou
uttp
pu
utt S
Stta
atte
e)):: Displays the current state of the input/output
devices (ON or OFF) listed here:
High Speed Relay/Electric
Heat
Hot Gas Solenoid
Condenser Inlet
Solenoid
Run Relay
Alternator Frequency
Drain Hose Heater
Run Relay Feedback
Diesel/Electric Relay (Model 50
units only)
Purge Valve
Alternator Excite Output
Electric Ready Input (Model 50
units only)
Defrost Damper
Electric Overload (Model 50 units
only)
Using the Sensors Key
The SENSORS key allows the operator to view the temperatures read by the
unit temperature sensors. To access the SENSORS menu press the
SENSORS key.
Figure 50.
Sensors Key
The first sensor display will appear. Press the NEXT and BACK keys to scroll
through the sensors. The Discharge Air Temperature sensor is shown
(
). Press the LOCK key to lock the current sensor on the
display.