36
TK 56704-1-OP-EN
IIm
mp
po
orrtta
an
ntt:: If the setpoint is changed using the + or - keys, the change must
be confirmed or rejected by pressing the YES or NO soft key
within 10 seconds of changing the setpoint.
•
If the YES key is pressed, the setpoint change made with the + or - key is
accepted, the setpoint changes, and the display returns to the Standard
Display.
•
If the NO key is pressed, the setpoint change made with the + or - key is
not accepted, the setpoint is not changed, and the display returns to the
Standard Display.
•
If either the YES or NO key is not pressed within 10 seconds of making a
change with the + or - key, the setpoint is not changed, and the display
returns to the Setpoint Display. The display briefly shows [SETPOINT
NOT CHANGED] and Alarm Code 127 Setpoint Not Entered is set, to
indicate that a setpoint change was started but not completed.
Figure 32.
Standard Display, New Setpoint
Starting the Diesel Engine
C
CA
AU
UT
TIIO
ON
N
R
Riisskk o
off IIn
njju
urry
y!!
The engine may start automatically any time the unit is turned on.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
Never use starting fluid. Damage to the engine can occur.
Diesel engine preheats and starts are automatic in both Continuous Mode
and CYCLE-SENTRY Mode. The engine will preheat and start as required
when the unit is turned on. The engine preheat and start will be delayed in
CYCLE-SENTRY mode if there is no current need for the engine to run. If any