TK 56704-1-OP-EN
21
There are two methods of defrost initiation:
S
SR
R--2
2//S
SR
R--3
3 M
Miiccrro
op
prro
occe
esssso
orr C
Co
on
nttrro
olllle
err:: The Microprocessor Controller is
programmed to automatically initiate timed and forced defrost cycles. The
SR-2/SR-3 uses temperature sensors to determine if forced defrost is
required.
M
Ma
an
nu
ua
all D
De
effrro
osstt:: Manual Defrost allows the operator to initiate a defrost
cycle by pressing the Defrost key. See “Initiating a Manual Defrost Cycle.”
TracKing™
T-90 series units are equipped with a wireless communication platform that
offers fleet owners the ability to monitor their refrigerated units. Cellular,
GPS, and Bluetooth capabilities communicate with Thermo King’s web-
based TracKing™ application, and Bluetooth with the Thermo King Reefer
App. A third party interface offers a gateway for telematics providers to
communicate with the Thermo King unit. To learn more about the TracKing
features, contact your Thermo King dealer.
SmartPower Electric Standby (Model 50 Units
Only)
The SmartPower Electric Standby option allows the unit to be operated on
either the diesel engine or external electric power.
D
DA
AN
NG
GE
ER
R
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
High voltage AC power is present whenever the unit is operating in the
Electric Standby mode and whenever the unit is connected to external
standby power. Voltages of this magnitude can be lethal. Exercise extreme
caution when working on the unit.
SmartPower Standard Features
The following features are standard equipment on units equipped with
SmartPower Electric Standby.
A
Au
utto
om
ma
attiicc D
Diie
esse
ell//E
Elle
eccttrriicc S
Se
elle
eccttiio
on
n:: The unit will automatically switch to
electric operation when a power cord is connected and the standby power is
switched On.
O
Ov
ve
errllo
oa
ad
d R
Re
ella
ay
y:: The overload relay is self-resetting.
H
Ho
ott G
Ga
ass H
He
ea
att:: Hot gas heat is utilized on all units.