CAUTION
Before cleaning, let the boiler cool down completely leaving two hours after
combustion terminated. Always wear a glove to protect your skin
NOTICE
When replacing the burner pot back in its, make sure that holes around burner pot flange
corresponds with the pins on burner plate, and the feeding part has the clearance for
pellts.
9.3. Ash removal
Open ash cleaning door, take the ash tray out, and empty it into a steel container. Ash
accumulated at the bottom of boiler should wiped out