At the end of season, before shutting down the boiler, we recommend
completely removing pellets from the hopper with the use of a vacuum
cleaner with an extension.
During periods of disuse, the boiler must be unplugged and placed in a
dry place protected from the elements. For greater safety, especially if
there are children around, we recommend removing the supply cable
from the rear of the boiler.
Upon re-start, when pressing the main switch (located on the back of
the boiler) does not make the control panel display light up, it could
mean that the service fuse needs replacing. On the rear of the boiler
there is a fuse holding compartment which is located underneath the
supply socket. Use a screwdriver to open the fuse-holder
compartment and if necessary replace them (5 AT delayed)
8
INSTRUCTIONS FOR INSTALLERS ONLY
8.1. Error masages
Both the keyboard touch screen and LCD you can view the messages on the main screen
such as error messages:
Er01
Security Error High Voltage 1. It may also intervene with the system off.
Er02
Security Error High Voltage 2. It can only intervene if the fan Combustive is active.
Er03
Extinguishing for low exhaust temparature
Er04
Shutdown over temparature water
Er05
Extinguishing due to high exhaust temperature
Er07
Encoder Error. The error may occur due to lack signal Encoder
Er08
Encoder Error. The error can occur due to problems of adjustment od the number
of revolutions
Er09
Water pressure low
Er10
Water pressure high
Er11
Clock Error. The error occurs due to problems with internal clock.
Er12
Extinguish for ignition failure.
Er15
Extinguishing due to power failure for more than 50 minutes
Er16
RS485 communication error
Er17
Adjusting the Air Flow Failed
Er18
Exhaustion Pellet