Leds
Function
Description
Button
Heating Resistance Led On: Heating Resistance On
Auger
Led On: Auger in the On interval
“
Led On: Pump On
L3
Valve
Led On: Valve On
L4
Output V2
Led On: Output V2 On
L5
Output Aux2
Led On: Output Aux2 On
L6
Output Aux3
Led On: Output Aux3 On
L7
Pellet Level
Led On: lack of pellet
External Thermostat Led On: contact open
Flow switch
Led On: Sanitary Water demand (contact closed)
Values Displayed in the main screen: The main temperature and the main thermostat. If
the keyboard is set as the local one, they are to be considered as the temparature of the
boiler probe and the value set for the boiler thermostat respectively. On the other hand, if
the keyboard is set as the remote one, they are to be considered the temperature of the
room probe iin the keyboard itself and the value set for room thermostat.
Operating states :
Check Up, Ignition, Stabilization, Modulation, Standby, Normal,
Safaty, Extinguishing, Recover Ignition, Block, Off.
7.2 The Menu
The menu of control panel consists of a User Menu and a Technical Menu in which you
can modify the operating parameters, test the outputs, check the history of the system.