Auger Calibration
Menu to change the Auger’s work time or speed. The system has 10 calibration’s steps
(0 value is set by the factory).
The calibration’s effect is valid only in Run Mode and
Modulation for the current recipe. For each step the value is increased or decreased of a
per cent value
P15
set in the Default Settings Menu.
Example Auger calibration witout encoder (P81=0=): P15=10%, Step=-1
Default Values
C03
=2,0
C04
=3,0
C05
=4,0
C06
=5,0
C07
=6,0
C11
=1,0
Calibrated Values
C03
=1,8
C04
=2,7
C05
=3,6
C06
=4,5
C07
=5,4
C11
=0,9
Fan Calibration
Menu to change the Combustion Fan speed.
The system has 10 calibration’s steps (the
0 value is set by the factory).
The calibration’s effect is valid only in Run Mode and
Modulation for the current recipe. For each step the value is increased or decreased of a
per cent value
P16
set in the Combustion Fan Menu.
Fan Calibration Example:
P16
=5%, Step=+3
Default Values
U03
=1000
U04
=1200
U05
=1400
U06
=1600
U07
=1800
U11
=900
Calibrated
Values
U03
=1150
U04
=1380
U05
=1610
U06
=1840
U07
=2070
U11
=1030
Heating Fan Menu
Menu to change the system’s heating parameters.
It has some Submenu.
Boiler Thermostat
The menu which allows modifying
the Boiler Thermostat’s value. It is possible to program
the minimum and the maximum value of the Boiler Thermostat setting the
Th26
and
Th27
Thermostats.
Buffer Thermostat
Menu which allows to modift the Domestic Buffer Thermostat value. This Menu is visible
only setting the parameter P26=10 and P76=9.
Operation Phases
Check Up
This stage allows for the cleaning of the boiler and burner before the ignition phase.
-The exhaust fan on the burner run at full power to eliminate any dust or smoke (in the
event of a hot restart) from the boiler.
-All the system sensors are checked for correct connections.
Pre-Heating
This stage brings the ignition element to the correct temperature before loading the burner
with pellets.