Models
CT 12
CT 18
CT 24
CT 32
CT 40
Fuel specifications
Wood pellets size 6 mm
Fuel parameters shall comply to EN 14961
Boiler class
Class 5 acc to EN 303/5
Operation mode
With fan at flue exhaust working under pressure
Maximum power output
kW
15
20
26
34
45
Minimum power output
kW
4,5
5,7
7,8
10,2
13,5
Efficiency at max output
%
91,2
88,8
89
89,1
89,3
Efficiency at min output
%
89,3
88,9
89,2
88,4
89,5
Flue gas temperature at max
power
o
C
116
119
125
124
113
Flue gas temperature at min
power
o
C
84
73
80
90
79
Net weight
kg
160
165
185
225
250
Water content
lt
44
40
45
70
76
Fuel container capacity
kg
75
90
100
115
lt
120
145
155
180
Fuel filling opening size
mmXmm
436x258
486x328
536x328
Combustion period
h
12
Minimum return temperature
o
C
40
o
C (with non-condensing working conditions)
CO emission
EN 303/5 Class 5
Required draft at chimney
Pa
8-10
10 - 12
12
–
15
Temperature control range
o
C
45
–
80
Max operating temperature
o
C
80
Max operating pressure
bar
3
Water flow/return
connections
F, R
1 “ (male)
Filling/draining connection
FD
½ “ (male)
/ 1” (male) for
S/X-PACK
Burner design
Stainless steel cylindrical pot
External dimensions
Height of boiler H
mm
1365
1490
1620
1670
Width of boiler W
mm
850
850
900
Height, fluegas pipe H1
mm
1195
1235
1360
1490
1540
Height, outfeed pipe H2
mm
1050
1085
1210
1340
1390
Height,return feed pipe H3
mm
325
360
Height,return feed pipe H4
80
Depth of boiler L
mm
520
570
620
Exhaust Outlet Diameter D
mm
80
130
Electrical supply
230V / 50Hz 6,3A
Power consumption (fan+gear
motors)
W
75 on S-models
125 on X-models
Power consumption (pump)
W
50 (S/X-PACK models)
Power consumption (ignitor)
W
165