Er23
Boiler probe or Back boiler probe or probe Buffer open
Er25
Engine cleaning broken
Er26
Engine cleaning 2 broken
Er27
Depression below the minimum threshold
Er34
Depression above the maximum threshold
Er52
Error Module I/O I2C
Other Messages
Sond
Displaying the status of the Temperature Sensors. The message is displayed
during the check-up and indicates that the temperature reading on one or more
probes is equal to the minimum value or the maximum value (depending on the
probe considered). Check that he probes are not open (read the minimum value of
the temperature scale) or short (read the maximum value of the temperature scale).
Service
Message that signals the achievement of scheduled operating hours. It's necessary
to call for service.
Cleaning
Message that signals the achievement of scheduled operating hours. It's necessary
to clean the stove or boiler.
Ignition
Block
Message that appears if the system is not manually turned off during Power On
(after preload): the system will turn off only when it is arrived at running.
Er20
Sensor Grid closed with system in operation Pellets
Port
Door open
Er06
Thermostat Pellet open
Link Error
Lack of communication between keyboard and control board
8.2. Combustion Management Menu
Menu to chage the combustion parameters.
Pellet Power
This Menu allows to set the system’s combustion in
automatic or manual mode in Pellet
modality. If the manual mode is set, the user can choose the combustion power.
Combustion
Description
1
–
Number of user
power
Power manually set from 1 to Number of User Power
(parameter
P03
)
Auto
Combustion Power set automatic by the system
Combustion Recipe
The Menu to select the combustion recipe in Pellet modality. The maximum value is the
number of recipes visible to the user (parameter
P04
). If
P04
=1 the Menu isn’t visible.