POWERMASTER 400SP, 500SP AUTOMATION
7-4
Octobe
r
30, 2008
7.04 Error Codes
In case of a malfunction, an e
rr
o
r
code is indicated on the digital multifunction display
(54)
and the co
rr
e-
sponding e
rr
o
r
desc
r
iption appea
r
s on the LCD display
(50)
. As long as an e
rr
o
r
code is indicated, welding
ope
r
ation is not possible.
*1 Check module temperatures in menu Extras, Diagnosis > Module temperatures
*2 Check supply voltages in menu Extras, Diagnosis > Operating voltages
*3 Check the flow rate in menu Extras, Diagnosis > Flow rate cooling system
Code Description
Cause
Remedy
E01
Thermal overload
Thermal sensor of power unit measures a too
high temperature (>176°F)
Let machine cool down in standby (*1)
Check temperature sensor (short circuit)
E02
Mains overvoltage
Mains voltage too high (24V supply > 36V)
Check mains voltage and control
transformer (*2)
E03
Secondary over-current
Welding current is too high
Notify an accredited Thermal Arc Service
Provider for repair
E04
Air cooling error
Temperature sensor of the power unit
detects that the unit heats up too fast
Check fans and their wiring
E05
Cooling system error
Flowrate of the cooling liquid is too low (< 0,3
l/min)
Pump is not working
Check connectors of flow-meter, level of
cooling liquid and flowrate (*3)
Check fuse SI7 (2,5A) on pc-board MV-
MAPRO
E06
Secondary overvoltage
Master detects output voltage is too high
(>100V)
Notify an accredited Thermal Arc Service
Provider for repair
E07
EEProm checksum error
No welding program stored or error during
reading from memory
Transfer welding programs to machine
again, exchange MV-MAPRO if error still
persists
E08
Wire feed / tacho
Power consumption of wire feed motor too
high
No tacho signal
No CAN-Bus connection between MAPRO
and DMR
Blow out torch package with compressed
air
Check wire feed unit
Check wiring of wire feed motor and PC-
board DMR
E09
Error v/a measuring
Measuring difference between Master and
Process
Check wiring of pc-board LSW, pc-board
DP-EMV and PC-board DP-UFI-BO
E11
Remote-control connection
Short circuit between remote control cables
Check remote control and wiring of remote
control socket
E12
Communication Process
Process is not responding to Master
Switch the machine off and on again
Optionally exchange PC-board DP-MAPRO
E13
Temp. sensor error
Temp. sensor is defective
Notify an accredited Thermal Arc Service
Provider for repair
E14
Op. voltages error
Supply voltage is too low (< 17V)
Check mains voltage and control
transformer (*2)
E16
Overcurrent protection1
Power consumption of power unti 1 is too
high
Notify an accredited Thermal Arc Service
Provider for repair
E17
Op. voltage 18V error
18 V from control transformer missing
Check mains supply and control
transformer
E18
overload protection
Safety shutdown to protect electrical
components
Temp. sensor is disconnected
Let machine cool down in standby
Check temp. sensor
E19
Power module error
Chargeup time for capacitors >1 second
Check mains input
Check MVPWRUP board and it’s wiring
E20
Overvoltage sec.
Process reports a too high output voltage or
no voltage
Notify an accredited Thermal Arc Service
Provider for repair
E21
Output voltage/current
External current/voltage or measure-
difference between Master and Process
Notify an accredited Thermal Arc Service
Provider for repair
E22
Mains undervoltage 1
Power unit 1 reports mains voltage too low
Check mains voltage and mains rectifier
E23
Mains overvoltage
Power unit reports mains voltage too high
Check mains voltage
E24
Overcurrent protection2
Power consumption of power unti 2 is too
high
Notify an accredited Thermal Arc Service
Provider for repair
E25
Power module detection
DIP-switch on pc-board MVDRV have been
set wrong
Notify an accredited Thermal Arc Service
Provider for repair
E26
Error voltage symmetry
DC-link voltage difference (>50V) between
power units
Notify an accredited Thermal Arc Service
Provider for repair
E27
No program (DSP)
Wrong material-wire-gas combination
Welding programs faulty or not available
Select other material-wire-gas combination
Transfer welding programs to machine
again
E30
Op. voltage 15V error
Supply voltage is too low
Check mains voltages
E31
Communication error
Master is not responding to Process
Switch the machine off and on again
?
A “?“ is shown in the display The display board doesn’t get any data from
the MV-MAPRO
Check the flat ribbon cable of the DS20BF
Check interpass hose (only machines with
separate wire feeder) and it’s connectors
Check PC-boards DMR and MV-MAPRO
Summary of Contents for POWERMASTER 400SP
Page 2: ......
Page 22: ...POWERMASTER 400SP 500SP AUTOMATION 2 6 October 30 2008...
Page 34: ...POWERMASTER 400SP 500SP AUTOMATION 3 12 October 30 2008...
Page 46: ...4 12 October 30 2008 POWERMASTER 400SP 500SP AUTOMATION...
Page 66: ...POWERMASTER 400SP 500SP AUTOMATION 6 8 October 30 2008...
Page 91: ...POWERMASTER 400SP 500SP AUTOMATION October 30 2008 9 13 Art A 08371...
Page 92: ...POWERMASTER 400SP 500SP AUTOMATION 9 14 October 30 2008...
Page 97: ...POWERMASTER 400SP 500SP AUTOMATION October 30 2008 A 5 Art A 07729...
Page 105: ......
Page 108: ......