![Thermador PRL304EG Service Manual Download Page 81](http://html.mh-extra.com/html/thermador/prl304eg/prl304eg_service-manual_1102846081.webp)
Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
58300000156573_ARA_EN_B
Page 82 of 119
4.6.10 Bake Burner Solenoid Removal and Replacement – Back
of Range
Access for the bake burner solenoid valve is at the back of the range
for all 48-inch models, or from the top of the range under the maintop
for all 36-inch and 30-inch models (see
Removal and Replacement – Under Maintop,
page
).
For the procedure for the XLO burner solenoids, see
page
NOTE:
For 48-inch ranges, part numbers differ for the main (large)
oven and auxiliary (small) oven solenoid valves.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 160: Bake Solenoids and Bake / Broil Manifold Assembly
1
Gas flex tube to small oven bake burner
2
Solenoid valve for small oven bake burner
3
Solenoid valve for large oven bake burner
4
Gas flex tube to large oven bake burner
5
Manifold for bake and broil burners
1. Follow all safety precautions and steps in
.
2. Remove the backguard (see
Backguard and Island Trim Removal
, page
3. Remove the back panels (see
, page
.
4. Remove solenoid valves from manifold arm (see Figure 160).
NOTE:
When removing a solenoid valve from the manifold arm
(see Figure 160), since it is secured with pipe sealant you may
need to use a hammer to tap at the wrench affixed to the nut at
the inlet valve until it can be rotated.
NOTE:
When installing a solenoid valve, the inlet must be sealed
with pipe sealant at the manifold
5. At the solenoid valve outlet, remove and retain the fittings:
When removing the main oven solenoid valve:
At the
outlet, a sleeve and a 9/16th inch compression nut attach to
the respective 3/8th inch diameter gas flex tube (see
Figure 161, page 83).
When removing the auxiliary oven solenoid valve:
At the
outlet, a
sleeve and a 1/2 inch compression nut attach to the
respective 5/16th inch diameter gas flex tube (see Figure 161,
page 83).
6. Replace the solenoid if needed.
NOTE:
Use pipe sealant on
pipe threads only
(for example, on
the solenoid valve inlet (at their outlets on the manifold arm).
Never use pipe sealant on the flair connections or pressure fittings,
such as the flared end of the flared adapter.