Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
58300000156573_ARA_EN_B
Page 103 of 119
Figure 207: Electrode Wire and Portal
1
Portal for electrode wire
2
Electrode wire (green)
3. Remove and retain the single screw that secures the electrode to
the bracket (see Figure 208), as well as the two screws that
secure the bracket to the burner box chassis (see Figure 209).
Then remove the electrode and bracket.
4. Replace the electrode if needed.
Figure 208: Electrode
1 Electrode
terminal
2
Location of screw that secures electrode onto
bracket
Figure 209: Electrode Bracket
1
Location of screw that secures electrode onto
bracket
2
Location of screws (2) that secure bracket to burner
box
Gas Leak Testing
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test.