Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
58300000156573_ARA_EN_B
Page 75 of 119
Figure 145: Back Panel
1
Screws (number depends on model)
4.6.3 Crossmember Cover Removal and Replacement
You will need to remove the crossmember cover if you are removing a
wire connector to the bake burner HSI or bake burner electrode.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 146: Crossmember Cover
1. Follow all safety precautions and steps in
page
.
2. Remove and retain the screws from the crossmember cover (see
Figure 146 and Figure 142, page 74).
3. [If removing the crossmember cover]: Push the power cord
through the receptacle on the crossmember cover, so that you can
remove it without having to detach the power cord wiring at the
terminal block.
4. [If replacing the crossmember cover] You will need to detach the
power cord from the terminal block first (see
Connections at the Terminal Block
, page
), and then replace the
crossmember cover.
4.6.4 Dilution Flue Removal and Replacement
You may need to remove the dilution flue if you need access a broil
burner assembly.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 147: Dilution Flue
1. Follow all safety precautions and steps in
.
2. Remove the backguard, per
Backguard and Island Trim Removal
procedure, page