![Thermador PRL304EG Service Manual Download Page 78](http://html.mh-extra.com/html/thermador/prl304eg/prl304eg_service-manual_1102846078.webp)
Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
58300000156573_ARA_EN_B
Page 79 of 119
4.6.7.1
Air Interlock Switch Removal and Replacement
The air interlock switch can be removed and replaced independently
of the cooling fan.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 154: Air Interlock Switch
Figure 155: Bracket
1. Follow all safety precautions and steps in
.
2. Remove the backguard, per
Backguard and Island Trim Removal
procedure, page
.
3.
Remove back panel, per
Back Panel Removal and Replacement
procedure, page
4. At the cooling fan, remove and retain the nuts securing the air
interlock switch onto its bracket (see Figure 154, Figure 155, and
Figure 156).
5. Replace the air interlock switch if needed.
Figure 156: Air Interlock Switch on Cooling Fan
1 Bracket
2 Air
interlock
switch