Texmate Tiger 380 Series Programming Manual Download Page 18

18

2 February, 2005   Code Sheet V4.01d (NZ1001)

3

38

80

0   S

Se

erriie

es

s

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 1

X52

X53

X54

X55

X60

DISPLAY

X63

X65

X66

X67

X64

X50

X51

X62

X61

SOURCE

SOURCE

SOURCE

SOURCE

SOURCE

SOURCE

DISPLAY

DISPLAY

DISPLAY

DISPLAY

DISPLAY

DISPLAY

DISPLAY

X72

X73

X74

X75

X76

X77

X70

X71

CHARACTER

CHARACTER

CHARACTER

CHARACTER

CHARACTER

CHARACTER

CHARACTER

CHARACTER

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 2

PRESCALER

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 3

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 4

PRESCALER

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 5

SMART INPUT MODULE

SETTINGS

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 6

SMART INPUT MODULE

SETTINGS

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 7

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 8

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 9

SUB-SETTINGS

1st DIGIT

2nd DIGIT

3rd DIGIT

CODE 10

2XX COLOR 1

BARGRAPH COLORS

COLOR 2

COLOR 3

COLOR 4

COLOR 5

COLOR 6

COLOR 7

SCALING FOR LINEAR BARGRAPH

3X0

BAR LOW

BAR HIGH

BAR NOMINAL

3X1

BAR LOW

BAR HIGH

BAR NOMINAL

SCALING FOR LOGIRITHMIC BARGRAPH

3X3

REFERENCE

BAR NOMINAL

3X4

REFERENCE

BAR NOMINAL

3X5

REFERENCE

BAR NOMINAL

3X6

REFERENCE

BAR NOMINAL

3X7

REFERENCE

BAR NOMINAL

Not yet available

SMART INPUT MODULE

SETTINGS

Summary of Contents for Tiger 380 Series

Page 1: ...isplay text editing Configuration data copying Downloading macros to the meter Tamper proof settings Tiger 380 Series controllers except the DI 802 have tamper proof lockout switches to prevent users...

Page 2: ...e holding both buttons press the Prog button then release all three buttons Press and hold the and buttons Programming Tip The Model and Software Code Version check ing procedure can be performed at a...

Page 3: ...n the controller is powered up Macros can be installed in the controller at the factory during initial programming or by the cus tomer at some later date Macros are written and compiled using the Tige...

Page 4: ...put pins on the rear of the con troller Display test pin Hold pin Lock pin The Setpoint and Relay Control Settings diagram on Pages 12 to 14 shows the three digit configuration settings that are appli...

Page 5: ...Port 2 3 Port 3 Converting F to C See User Notes on Page 21 for a procedure See CH1 Thermocouple Calibration on Page 21 for a procedure See CH1 RTD Calibration on Page 22 for a procedure CHANNELS 5 6...

Page 6: ...t input module data sheet for setup procedures Use buttons to set CAL_LO Use buttons to set CAL_HI 0 Manual Calibration requires NO input source 1 2 point Calibration requires dual input source 2 Cali...

Page 7: ...signal channel must be selected in the 3rd digit when configuring a lin earization table using the auto setup mode 0 1 CH1 2 CH2 3 CH3 4 CH4 5 CH5 6 CH6 7 CH7 THIRD DIGIT THIRD DIGIT THIRD DIGIT Use...

Page 8: ...NDARY display is the bargraph display Note 3 These functions are only available on selected input modules Note 4 If Code 1 s display modes have been entered second digit set to 5 6 or 7 the display wi...

Page 9: ...r 2 2 Output Register 3 3 Output Register 4 4 Output Register 5 5 Output Register 6 6 Output Register 7 7 Smart Input Module Register 1 Code Setup See Note 6 THIRD DIGIT FIRST DIGIT SECOND DIGIT CODE...

Page 10: ...1 Frequency 999 99 Hz range from 0 01 Hz 2 Frequency 99 999 kHz range from 1 Hz 1 s gate 3 Frequency 500 kHz range from 10 Hz 0 1 s gate 4 Pulse 50 0000 s 100 s resolution 5 Period 999 99 ms 10 s reso...

Page 11: ...ear FIFO Buffer 3 Reset Buffer Number to 0 Note Setting Code 8 to 3XX resets the data log buffer to 0 Once reset Code 8 must be set back to the required data log buffer setting DATE TIME STAMP OPTIONS...

Page 12: ...Relay Reset 4 Relay Latched Off 5 Mode Hysteresis Deviation PID SP Flashing SP Tracking 6 Timer Modes OFF Normal Delay Repeat ON Pulse ON 1 Shot ON Repeat OFF Pulse OFF 1 Shot OFF Note In PID Mode al...

Page 13: ...o 6553 5 65 535 secs On_t 0 1 0 001 to 6553 5 65 535 secs Off time oFF_t 0 1 0 001 to 6553 5 65 535 secs Off time oFF_t 0 1 0 001 to 6553 5 65 535 secs Minimum off time M_of 0 1 to 6553 5 secs Set Up...

Page 14: ...ct reset trigger from 1 of 4 relay operating edges Reset Trigger Select register to be reset Reset Destination Register Select Reg in reset mode Reset Mode Copy contents of selected register SP1 to SP...

Page 15: ...ble CONST This mode stores a user defined constant into the selected destination regis ter In most cases this number will be zero but it can be any number I S C This mode stores the current input valu...

Page 16: ...nual Calibration 2 point Calibration INPUT INPUT 111 ZERO SPAN INPUT INPUT 112 ZERO SPAN INPUT INPUT 113 ZERO SPAN INPUT INPUT 114 ZERO SPAN INPUT INPUT 025 SPAN 035 ZERO SPAN 045 CHANNEL 055 CHANNEL...

Page 17: ...Analog Output 152 CAL LOW CAL HIGH OUTPUT OUTPUT SOURCE SOURCE 1st DIGIT 2nd DIGIT 3rd DIGIT SUB SETTINGS TC TYPE UNITS TC TYPE UNITS TC TYPE UNITS 121 ZERO SPAN INPUT INPUT Calibrate RTD 122 ZERO SPA...

Page 18: ...IGIT CODE 4 PRESCALER 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 5 SMART INPUT MODULE SETTINGS 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 6 SMART INPUT MODULE SETTINGS 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 7 1st DIGIT 2...

Page 19: ...ING SPAN PB INT DER ARW MCT SP TRACKING SPAN PB INT DER ARW MCT SP TRACKING TIMER MODE SETTINGS SPC_1 _ _ 6 SPC_2 SPC_3 SPC_4 SPC_5 SPC_6 _ _ 6 _ _ 6 _ _ 6 _ _ 6 _ _ 6 SPC SETTING NORMALLY OFF PULSED...

Page 20: ...setpoint with the contents of a selected source register Setpoint Control Settings XX7 Select the contents of one register to be copied into another register by a setpoint The 38 named registers that...

Page 21: ...he Calibration mode CAL set to 111 and fine tune the thermocouple calibration over the required temperature range Fine Tune Calibration over Specific Temperature Range Follow Steps 1 to 5 for setting...

Page 22: ...ls 2 and 3 using the following settings CH2 Code 4 210 for type 385 CAL 132 to calibrate type 385 Code 4 2X0 to select specific RTD CAL 112 to fine tune selected RTD CH3 Code 5 X31 for type 385 CAL 13...

Reviews: