Set Deviation from 1 to 65535
counts. Selected counts apply +
and – from setpoint value
Set the Span
Set the Proportional Band Value
Set the Integral Value
Set the Derivative Value
Set the Anti-reset Wind-up % PB
Set the Minimum Cycle Time
MIN 0.0%
MAX 999.9%
MIN 0
MAX 99999
MIN 0.0
MAX 6553.5
MIN 0
MAX 999.9
MIN 0.0%
MAX 100.0%
MIN 0.0 secs
MAX 1000.0 secs
Select Tracking Setting
to
Select Flash Setting OFF or ON
OFF= Tracking Off
1
= SPX tracks SP1
2
= SPX tracks SP2
3
= SPX tracks SP3
4
= SPX tracks SP4
5
= SPX tracks SP5
6
= SPX tracks SP6
Set Hysteresis from 0 to 65535
counts. Selected counts apply +
and – from setpoint value
From Page 12,
3rd digit [XX5]
From Page 12,
3rd digit [XX6]
Delay-on-make time (DOM)
0.1 to 6553.5 secs
Delay-on-break (DOB) time
0.1 to 6553.5 secs
Reset SPC_X to XX0
DOM 0.1 to 6553.5 secs
Minimum on-time (M_on)
0.1 to 6553.5 secs
On-time (on_t) 0.1/0.001
to 6553.5/65.535 secs
DOM 0.1/0.001 to
6553.5/65.535 secs
On-time (on_t) 0.1/0.001 to
6553.5/65.535 secs
DOB 0.1 to 6553.5 secs
Off-time (oFF_t) 0.1/0.001 to
6553.5/65.535 secs
DOB 0.1/0.001 to 6553.5/65.535 secs
On_t 0.1/0.001 to 6553.5/65.535 secs
Off-time (oFF_t) 0.1/0.001
to 6553.5/65.535 secs
Off-time (oFF_t) 0.1/0.001
to 6553.5/65.535 secs
Minimum off-time (M_of)
0.1 to 6553.5 secs
Set Up Hysteresis, Deviation & PID Mode Settings
Set Up Timer Delay Settings
XX
XX
Reset SPC_X to XX0
Programming Tip
If you do not require any
of the functions in this
mode, ensure it is set to:
Programming Tip
If you do not require any
of the functions in this
mode, ensure it is set to:
Normal Mode
1-Shot ON Mode
Pulse ON Mode
Repeat ON Mode
1-Shot OFF Mode
Pulse OFF Mode
Repeat OFF Mode
Normally OFF/Pulsed ON Modes
These are time control modes were the relay is
normally OFF (de-energizes)
and
pulses ON
(energizes)
when the setpoint activates.
Normally ON/Pulsed OFF Modes
These are time control modes were the relay is
normally ON (energizes)
and
pulses OFF
(de-energizes)
when the setpoint activates.
Note:
If minimum cycle time is set to 0, the relevant
relay is disabled. PID functions still operate
Set to 0 for PID 4-20 mA.
Set to MINIMUM 0.5 for SSR.
Set to 20 secs for Relays.
Single Actuation
Single Actuation
Single Actuation
Single Actuation
Multiple Actuation
Multiple Actuation
Single Actuation
Select Tracking Setting
to
Programming Tip
The TIMER mode can not be
accessed if the setpoint (SPC_1
to SPC_6) is in the PID mode.