PLACEMENT
Move the minipool into its final position, with the plumbing
fittings directed toward the channel carrying the pipelines
away from the pit.
Refit the legs and feet removed previously.
6
LEVELLING THE MINIPOOL
Drill the fixing centres in the floor, keeping to the distances
indicated in the drawing.
The screws (not supplied) should be steel, size M8x100,
driven into masonry plugs.
7
FITTING THE HANDRAIL
Drill the fixing centres in the floor, keeping to the distances
indicated in the drawing.
The screws (not supplied) should be steel, size M8x100, driven
into masonry plugs.
8
FITTING THE CANVAS
Position the canvas on the minipool. Secure suitable
anchorages (not supplied) to the deck, aligned with the
straps.
The canvas is not intended to carry weights.
Do not sit, step or lie on the canvas.
Do not place objects on the canvas.
The canvas can be dangerous if not secured or
properly closed.
Failure to abide by the instructions for fastening the
cover in place when the tub is left with water inside,
may represent a source of danger.
Remove the canvas completely before stepping into
the pool, otherwise there is a risk of being trapped.
9
PLUMBING CONNECTIONS
The contractor will supply all the plumbing material
(including fittings, ball valves, etc.), needed to connect the
minipool to the Spa-pack and to the overflow tank (not
supplied), and must install suitably proportioned gullies,
inspectable and accessible for cleaning purposes, into
which the drain pipelines will be directed.
DRAIN:
An outlet located in the base of the pool is
equipped with a grille and a 50mm diameter pipe extending
to the point where plumbing connections are made (pipe 6).
This is the connection by way of which filtered and heated
water is pumped into the pool; it can also be used for
draining the pool.
In particularly cold climates, where there is a risk of
residual water freezing in pipelines, it is advisable to
install drain valves at strategic points on the various
circuits, so that the system can be emptied completely.
IMPORTANT: before making any permanent connection
to the main drain, contact the local authorities to
check on regulations governing the disposal of
chemically treated water.
FILLING:
the recommended method of filling the Teuco
620HU is to use an ordinary hose, taking care not to
immerse the end as this could allow reflux of water back
into the main (3).
IMPORTANT: if the intention is to connect the minipool
permanently to the water supply, suitable non-return
devices must be incorporated to prevent reflux back to
the water main.
Contact the local authorities before proceeding with
this type of installation.
10
ELECTRICAL CONNECTIONS
The electrical power supply must be in compliance with
national statutory regulations in force.
For sizing purposes, we would like to specify that the max.
power absorption, as stated in the “electrical
characteristics” table, should be interpreted as rated power
absorption during operation.
The connection to the power supply must be permanent,
The item must be connected to the mains using a multi-
pole power switch
(I)
with a switch-contact gap that The
product must be connected to the mains power via an
omnipolar switch with an opening between contacts that
guarantees complete disconnection in condiction of
overvoltage category III (at least 3 mm), installed outside the
areas 0,1,2 (IEC 60364-7-701).
Make certain the appliance is connected to the power
source by way of a residual current device (RCD) with
action threshold = 30mA.
The appliance must be equipotentially bonded by making
the connection to the terminal (
) positioned on the
baseplate of the Spa-pack, near to one of the pumps.
2,5 m
2 m
1,5 m
2 m
1,5 m
ZONA 2
ZONA 2
ZONA 1
ZONA 0
ZONA 0
Make the power connection to the electrical panel using a
3-core cable of specifications suitable for the application,
which must be secured with the clamp provided on the
panel for the purpose.
The connection must be made utilizing the terminals of the
isolating switch and the earth bar located internally of the
panel (fig. 10).
Thereafter, make the power connection to the underwater
light (12V-2A), which requires a two-core cable (not
supplied). Specification: 2 x 1.5 H05VV-F.
Connect the wires to the panel using terminals 22 and 24,
securing the cable with the PG 13.5 clamp provided, and to
the light fitting by way of the relative terminal strip (fig. 10).
The underwater light must also be earthed, using a
suitable green-yellow wire (not supplied) of which the two
ends are connected respectively to the earth bar internally
of the panel (PG 7 clamp available), and to the screw on
the body of the fitting (fig. 10).
Secure both ends of the earth wire using suitable crimp
terminals and lockwashers.
Use the equipotential bonding terminal provided on the
baseplate of the Spa-pack to connect the equipment to the
earth system of the building.
Summary of Contents for 620HU
Page 4: ...MAX 8m 2320 400 A 800 400 63 A A 200cm Max 1310 910 S S 4 2 A B 3A A PH2 3B...
Page 5: ...5 B A 19 3C 3D A B 4...
Page 6: ...811 994 647 967 435 967 932 473 266 914 1029 352 352 8 A B 7 7 7 6 6 x7 5...
Page 7: ...7 300 1450 250 7 8...
Page 8: ...8 1 3 2 4 5 6 7 50 mm 63 mm 63 mm 80 75 mm 9 8 5 5 6 6 6 5 6 5 7 4 7 9...
Page 9: ...9...
Page 10: ...10 10...
Page 11: ...11 M5x10 5x10 M5x10 5x10 L L 1P 2P 3P 1R 2R 3R 22 24 12V 12V 12V I 1 I 2 I 6 L1 L2 L3 N...
Page 37: ...37...