Tetra IN 1000 plus Manual Download Page 4

UK

UK

Dear Customer,

Congratulations on 

choosing your new highly 

effi

  cient, easy to maintain,

Tetra Aquarium Filter.

The Tetra IN plus Internal Filter 
not only mechanically and 
biologically fi lters the water but 
also creates a natural water fl ow 
enriching the aquarium water with 
oxygen. Furthermore the Tetra IN 
plus is quickly and easily adjusted 
to perfectly suit the requirements 
of your aquarium. Please read 
the instructions carefully, before 
installing your new Tetra IN plus.

Tetra IN plus Internal Filter
A. Suction 

Cups

B. Mounting 

unit

C.  Air intake tube
D.  Adjustable venturi air intake
E.  Multidirectional water diff user 
F. Motor 

casing

G.  Flow rate adjuster
H. Double 

fi lter cartridge

I. Split 

fi lter media

J. Double 

fl ow inlet

K.  Split foam carrier

Instructions

Preparation for use (see fi g. 1)
Before installing the fi lter, attach 
the enclosed suction cups to 
the back of the mounting unit. 
Attach the air intake tube to the 
adjustable venturi air intake.

Installation and operation (fi g. 2)
Using the suction cups, attach the 
fi lter  at  your  chosen  position  to 
the inside of the aquarium glass, 
making sure that the top of the 
water diff user is placed maximum 
1 cm or less below the surface of 
the water so that the inlet end of 
the air intake tube is well above 
the water surface.
To start the fi lter simply plug it in!
 
Adjustment of water fl ow (fi g. 3)
Depending on stocking levels and 
the size of your aquarium it may be 
necessary to adjust the water fl ow 
through your Tetra IN plus.
To increase the water fl ow, 
turn  the  adjuster  Clockwise.  To
decrease the water fl ow, to turn 
the adjuster counterclockwise.

Adjustment of air fl ow (fi g. 4)
The larger the aquarium and the 
number of fi sh the greater the need 
for oxygen in the water. Using the 
adjustable venturi air intake the 
concentration of oxygen can be 
set to your requirements.
To increase the air fl ow, turn the 

adjuster towards the back of the 
fi lter. To decrease the fl ow,  turn 
the adjuster towards the front of 
the fi lter.

Adjustment of fl ow
direction (fi g. 5)
The multidirectional water 
diff user produces a water fl ow 
that corresponds to those found 
in the natural environment of 
your fi sh. To adjust the direction, 
simply rotate the nozzle through a 
maximum angle of 180° to suit your 
requirements.

Care and Maintenance
IMPORTANT! Always disconnect 
the fi lter from the electrical supply 
before removing it from the water 
or carrying out any maintenance 
upon it!
Cleaning and replacing the foam 
fi lter media (fi gs. 6 & 7)
During use the foam fi lter media 
will eventually become clogged 
with debris which may reduce 
both the air supply through the 
venturi air intake and the water 
fl ow through the fi lter.  Regular 
cleaning and/or replacement of 
the fi lter foam on a regular basis is 
necessary to ensure that the fi lter 
remains working effi

  ciently.

1. Cleaning the foam fi lter media
Remove the fi lter 

cartridge 

from the mounting unit. It is not 
necessary to remove the mounting 
unit  from the aquarium during 
normal maintenance (fi g. 6).
Remove the fi lter cover and with it 
the foam fi lter media (fi g. 7). One 
of the two foam fi lter media should 
then be rinsed in water from the 
aquarium. 
Foam fi lter media should never 
be cleaned using untreated tap 
water as the chlorine present will 
kill useful fi lter bacteria growing 
on its surface!

2.  Replacing the foam fi lter media
The foam fi lter media can be 
cleaned 2 to 3 times and reused 
before it requires replacement. 
Replacement fi lters are available 
from your local retailer.
When placing the foam fi lter media 
into the cartridge it is important to 
ensure that the foam is centered 
on the foam holder (see fi g. 7)
In models that contain two 
double fi 

lter cartridges, only 

the lower cartridge should be 
changed at any one time as 
per the following instructions;
(I) Remove the lower foam fi lter 
media and discard.
(II) Remove the upper double 

Tetra GmbH
D-49304 Melle, Germany
www.tetra.net

2 Years Guarantee
Tetra guarantees that your Tetra IN 
plus  will  be  repaired  or  replaced-
free of charge for two year from the 
date  of  purchase  if  it  fails  to  work 
because of faulty material or work-
manship.
This guarantee does not cover nor-
mal wear and tear, nor any deterio-
ration suff ered through overloading, 
improper use, negligence or ac-
cident. Similarly any modifi cations 
made by the purchaser to the appli-
ance will cause the guarantee to be 
null and void.
Please keep your receipt as proof of 
purchase. The guarantee does not 
cover  improper  use,  normal  wear 
and tear or any modifi cation made to 
the appliance. In case of complaints 
please contact your local retailer or 
address to Tetra (UK) Ltd., P.O. Box 
271, Southampton, S018 3ZX.

SAFETY FIRST!
Always isolate the unit from the 
mains electricity before carrying 
out any maintenance. The control 

unit of this fi lter cannot be replaced.
If this is damaged the fi lter 
must no longer be used. This 
Tetra  lN  Internal  Filter  is  only 
designed for use in tempera-
tures which do not exceed 35°C.
The supply cord cannot be replaced. 
If the cord is damaged the entire
appliance must no longer be used.
This appliance is not intended for 
use by persons (including children) 
with reduced physical, sensory or 
mental  capabilities,  or  lack  of  ex-
perience and knowledge, unless 
they have been given supervision 
or instruction concerning use of the 
appliance by a person responsible 
for their safety. Children should be 
supervised  to  ensure  that  they  do 
not play with the appliance.

For further information on fi sh keep-
ing please contact: The Tetra (UK) 
Ltd., P.O. Box 271, Southampton, 
S018 3ZX.
www.tetra.net

Technical Data

Model

Flow rate in

Litres/hour

Aquarium size

In litres

Number of double
Filter cartridges

IN 300 plus

150 – 300

10 – 40

1

IN 400 plus

200 – 400

30 – 60

1

IN 600 plus

300 – 600

50 – 100

2

IN 800 plus

400 – 800

80 – 150

1

IN 1000 plus

500 – 1000

120 – 200

2

fi lter cartridge and remove the 
foam fi lter  media.  Place  this  into 
the lower fi 

lter cartridge and 

reinsert into the mounting unit.
(III) The new foam fi lter  media 
should then be placed into 
the empty upper double fi lter 
cartridge, reinserted into the 
mounting unit and the fi lter 
restarted.
Replacing only one foam fi lter 
media at any one time ensures that 
at least 50% of bacterial activity 
in the fi lter is preserved ensuring 
fast and effi

  cient 

bacterial 

maturation of the new foam fi lter 
media.

Cleaning the impeller 
unit (fi g. 8)
The impeller unit should 
be cleaned each time the 
foam fi lter media is cleaned or 
replaced. Due to the Tetra Internal 
Filter’s innovative design this can 
be done quickly and easily as the 
fi lter mounting unit remains in the 
aquarium.
The impeller unit is easily removed 
from its housing as shown in
fi gure 8.
Do not use abrasive or caustic 
cleaning agents when cleaning 
the impeller unit.

If effi

  ciency is impaired, clean 

the fi lter.

6

7

Summary of Contents for IN 1000 plus

Page 1: ...Mat Nr TH50899 Tetra GmbH D 49304Melle Germany For more information www tetra net For more information www tetra net...

Page 2: ...8 Notice d emploi 10 Gebruiksaanwijzing 12 Istruzioni per l uso 14 Instrucciones de uso 16 Instru es de uso 18 Brugsanvisning 20 Bruksanvisning 22 Instrukcja obs ugi 24 N vod k pou it 26 28 Instruc iu...

Page 3: ...4 5...

Page 4: ...n its surface 2 Replacing the foam filter media The foam filter media can be cleaned 2 to 3 times and reused before it requires replacement Replacement filters are available from your local retailer W...

Page 5: ...einigungsmittel verwenden 2 Auswechseln Ein Filtermedium k nnen Sie zwei bis dreimal reinigen und wieder benutzen Danach l t seine Filteraktivit t nach und es sollte ausgewechselt werden Ersatzfilter...

Page 6: ...ovenant de l aquarium ceci afin de pr server au maximum les colonies de bact ries utiles qui se sont d velopp es Ne jamais utiliser de d tergents ou d autres produits d entretien Lereplacementet oulen...

Page 7: ...tspoelenin bij voorkeur aquariumwater om zoveel mogelijk van de bacterieculteres in tact te houden Gebruik in geen geval reinigungmiddelen 2 Vervangenvanhetfiltermedium Een filterpatroon kunt U twee d...

Page 8: ...rattata con Tetra AquaSafe Gli elementi filtranti in spugna non devono mai essere puliti in acqua di rubinetto non trattata perch il cloro presente in essa ucciderebbe l utile flora batterica presente...

Page 9: ...tivos bacterianos De ninguna manera utilizar productos de limpieza 2 Sustituci n Usted puede limpiar yreutilizar un medio filtrante dos o tres vedes Despu s su actividad filtrante disminuye y conviene...

Page 10: ...das duas esponjas filtrantes deve ser lavada com gua do aqu rio ou com gua tratada com Tetra AquaSafe A esponja filtrante nunca deve ser lavada com gua da toneira n o tratada uma vez que a presen a d...

Page 11: ...underingenomst ndigheder reng ringsmidler 2 Udskiftning De kan reng re og genbruge et filtermedietotiltregange Derefter falderdetsfilteraktivitetogDeb r udskifte det Erstatningsfiltre f r De hos Deres...

Page 12: ...teriekulturer som m jligt Anv nd aldrig reng ringsmedel 2 Byte Ett filtermedium kan reng ras och teranv ndas tv till tre g nger D refter f rs mras filteraktiviteten och det b r bytas ut Reservfilter f...

Page 13: ...e prowadzi do spadku efektywno ci filtracji i dlatego wk ad powinien zosta wymieniony Wymienne wk ady s dost pne w sklepach zoologicznych W modelach z 2 dwukomorowymi zasobnikami nale y czy ci lub wy...

Page 14: ...ikr t vy istit a zase pou t Pot klesne jeho filtra n aktivita a m lo by b t vym n no N hradn filtr najdete u sv ho specializovan ho obchodn ka U model s dvojit mi filtra n mi komorami se ist nebo vym...

Page 15: ...8 19 2 117647 10 39 196084 42 115230 2 2 Tetra IN plus Tetra GmbH 1580 49304 Tetra GmbH Kundenservice Postfach 1580 49304 Melle Tetra IN plus Tetra IN plus 35 IN 300 plus 150 300 10 40 1 IN 400 plus 2...

Page 16: ...nicio situa ie nu este permis utilizarea de solu ii de cur are 2 nlocuire Pute i cur a i refolosi un mediu de filtrare de dou p n la trei ori Ulterior scade eficien a filtrului i se impune nlocuirea...

Reviews: