Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
5
18
TELELIFT 3713 Elite - 4017 - 4514
TROUBLESHOOTING
Trouble
Cause
Solution
The beacon does not function
The engine water temperature
indicator does not function
The hydraulic oil temperature
indicator does not function
The fuel gauge does not function
The emergency pump do not work
Turn signals' lamps damaged
Fuse
F4
damaged
Beacon (
X101
) damaged
Beacon lamp (
X101
) damaged
Fuse
F9
damaged
High water temperature thermostat (
B13
)
damaged
High water temperature indicator (
P1
)
damaged
Fuse
F9
damaged
Hydraulic oil temperature thermostat
(
B16
) damaged
Hydraulic oil temperature indicator (
P2
)
damaged
Fuse
F9
damaged
Fuel level float (
B12
) damaged
Fuel level indicator (
P3
) damaged
Fuses
F4G
and
F20
damaged
Check the lamps and replace if
necessary.
Check the fuse and replace if
necessary.
Check you have 12V on connector
X26
to pin
6
; or change the beacon.
Check the lamp and replace if
necessary.
Check the fuse and replace if
necessary.
Check the thermostat and replace if
necessary.
Check you have 12V between pins
6
and
3
of connector
XP1
. Or change
the indicator.
Check the fuse and replace if
necessary.
Check the thermostat and replace if
necessary.
Check you have 12V between pins
6
and
3
of connector
XP2
. Or change
the indicator.
Check the fuse and replace if
necessary.
Check the float and replace if
necessary.
Check you have 12V on connector
XP3
to pin
1
and there is continuity between
pins
3
and
4
and the ground; if
necessary, change the indicator.
Check the fuses and replace if
necessary.
Summary of Contents for TELELIFT 3713 Elite
Page 4: ...Courtesy of Crane Market...