TROUBLESHOOTING
When key is turned to 1, the
dashboard is not powered
The machine cannot be started from
the driving cab
Battery discharged
Battery coutout switch
Ground
50A fuse
F2G
blown.
Ignition key block
Fuses-relays board damaged
Relay
K05
damaged.
Ignition key
Relay
K11
damaged
Speed selector
SX12
15A fuse
F5G
Socket
X17
on fuses board
Problem on the line from dashboard to
engine box
Check the battery, replace if necessary.
Check that the switch is in the correct
position and it works fine. Replace if
damaged.
Check that the ground braid between
chassis and engine is correctly
connected and intact.
Check the fuse; replace if necessary.
Check that contact
30
of the ignition
key is powered; if you have not 12V on
contact
15/54
, change the key.
Check you have 12V on connector
J2
of the board, or replace the board.
Check the 50A
F3G
, the connections
and, if necessary, replace the relay.
Check that contact
50a
of the key
supplies 12V when the key is in the start
position (turned right).
Check the relay; replace if necessary.
Check if the speed is engaged or
change the speed selector.
Check the fuse; replace if necessary.
Check if you have 12V on pin
8
of
connector
X17
when the key is turned
to the start position.
Check the continuity between pin
8
of
connector
X17
and pin
85
of relay
K01
located in the engine box.
Problem
Cause
Solution
5.3
ELECTRIC FAULTS
Summary of Contents for TELELIFT 3713 Elite