![TEREXLIFT TELELIFT 3713 Elite Workshop Manual Download Page 150](http://html1.mh-extra.com/html/terexlift/telelift-3713-elite/telelift-3713-elite_workshop-manual_1088903150.webp)
Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
5
14
TELELIFT 3713 Elite - 4017 - 4514
TROUBLESHOOTING
Trouble
Cause
Solution
The right outrigger does not move
up
No sway to the right
No sway to the left
Low boom sensor (
B38
) damaged
Outrigger switch
S2
damaged
Tecnord control unit damaged
Solenoid
Y10-F
damaged
Low boom sensor (
B38
) damaged
Sway switch
S3
damaged
Tecnord control unit damaged
Solenoid
Y15-B
damaged
Low boom sensor (
B38
) damaged
Check the sensor ; check you have 12V
on connector
J1
on pin
3A
; change the
sensor, if necessary.
Check you have 12V on contact
3
of
the switch, and 12V on contact
7
of the
switch when the movement is
done.Change the switch, if necessary.
Check you have 12V on connector
J1
on pin
5A
and on connector
J2
to pin
3A
when the movement is done; if
necessary, change the control unit.
During movement, check you have 12V
between the two contacts of the coil;
or change the solenoid.
Check the sensor ; check you have 12V
on connector
J1
on pin
3A
; change the
sensor, if necessary.
Check you have 12V on contact
3
of
the switch, and 12V on contact
7
of the
switch when the movement is
done.Change the switch, if necessary.
Check you have 12V on connector
J1
on pin
6A
and on connector
J2
to pin
6A
when the movement is done; if
necessary, change the control unit.
During movement, check you have 12V
between the two contacts of the coil;
or change the solenoid.
Check the sensor ; check you have 12V
on connector
J1
on pin
3A
; change the
sensor, if necessary.