Service and Repair Manual
July 2021
Platform Components
24
S
®
-60 DC • S
®
-60 FE
Part No. 1299608GT
5 Remove the pin retaining fasteners from the
jib boom and jib boom leveling arms to
platform rotator pivot pins. Do not remove the
pins.
6 Use a soft metal drift to remove both pins and
remove the platform rotator from the machine.
Crushing hazard. The platform
rotator could fall when removed
from the machine if not properly
supported.
Note: When installing the platform rotator
fasteners, torque the fasteners to specifications.
Refer to Specifications,
Machine Torque
Specifications
.
How to Bleed the Platform
Rotator
1 From the ground controls, fully rotate the
platform to the right and then the left.
Continue holding platform rotate in each
direction for approximately 10 seconds.
2 Repeat this procedure until the air has been
bled out of the platform rotator.
Note: Verify by pushing and pulling the platform
side to side by hand. There should be minimal
movement.
Summary of Contents for Genie S-60 DC
Page 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Page 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Page 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Page 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Page 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Page 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Page 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Page 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Page 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Page 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Page 171: ......