Service and Repair Manual
July 2021
Platform Controls
20
S
®
-60 DC • S
®
-60 FE
Part No. 1299608GT
13 Momentarily activate the drive enable toggle
switch in the right direction to save the value.
Result: The alarm will sound indicating the
setting has been saved. Continue to the next
desired Ramp time adjustment.
Ramp Rate (factory settings)
Primary boom up/down
ramp accelerate (up)
ramp decelerate (down)
2 seconds
0.6 second
Turntable rotate
ramp accelerate (up)
ramp decelerate (down)
1.5 seconds
1.25 seconds
Extend/Retract
ramp accelerate (up)
ramp decelerate (down)
2 seconds
0.4 seconds
Jib up/down
ramp accelerate (up)
ramp decelerate (down)
2 seconds
0.4 second
Platform rotate
ramp accelerate (up)
ramp decelerate (down)
0.75 second
0.3 second
Propel
ramp accelerate (up)
ramp decelerate (down)
5 seconds
3 seconds
Platform level
ramp accelerate (up)
ramp decelerate (down)
1 second
0.4 second
1-2
How to Calibrate Boom Angle
Sensor
Boom angle sensor is installed on the primary
boom sections. The angle sensor is used to detect
whether the boom is stowed or not stowed. A two
point calibration procedure captures the signal with
the cylinder fully extended and fully retracted to an
angle measurement that is scaled to degrees
within the program. If the angle sensor is in the
uncalibrated state, drive speed is limited to out-of-
stowed speed.
Note: Start this procedure with the boom in a
stowed position. Position the machine in a suitable
location with sufficient vertical space. Refer to
Navigation Menus,
Settings Menu
.
Note: The one point calibration is optional. It
allows 2 mph / 3,2 Km/h travel if machine needs to
be immediately moved.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2 Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
3 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
Result: The display will show FAULTS.
4 Momentarily activate steer in the right
direction until SETTINGS is shown on the
display.
5 Momentarily activate the drive enable toggle
switch in the right direction until VALVE AND
SENSOR SETTINGS is shown on the display.
6 Momentarily activate the drive enable toggle
switch in the right direction until CALIBRATE
TILT SENSOR is shown on the display.
Summary of Contents for Genie S-60 DC
Page 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Page 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Page 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Page 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Page 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Page 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Page 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Page 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Page 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Page 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Page 171: ......