In addition to the 10 LEDs that FPGA device can control, there are 4 indicators which can indicate
the board status (See
Figure 3-9)
, please refer the details in
Table 3-1
Figure 3-9 LED Indicators on MAX 10 NEEK
Table 3-1
LED Indicators
Board Reference LED Name
Description
D13
5V Power
Illuminate when 5V power is active.
D14
2.5V Power
Illuminate when 2.5V power is active.
D16
1.2V Power
Illuminate when 1.2V power is active.
D6
CONF_DONE
Illuminate when configuration data is loaded into MAX 10
device without error.
D7
JTAG_RX
Illuminate during data is uploaded from MAX 10 device to PC
through UB2.
D8
JTAG_TX
Illuminate during configuration data is loaded into MAX 10
device from UB2.
TXD
TXD
Illuminate during transmitting data via USB.
RXD
RXD
Illuminate during receiving data via USB.