PLDC04452
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
5
2
If it switches, go to point 6.
If on, empty the dirty water tank.
If the connection is intact go to point 5.
Otherwise restore the connection / connector.
Doesn’t switch, replace or check wiring.
Check whether the display on the instrument
panel shows error code "AcA".
Check the connection of the suction motor.
Check the fuse F, see paragraph D5.1.
Check if the “tank full” light on the instrument
panel board is on.
2
The solenoid valve remains closed, go to point 3.
Check operation of relay C, see paragraph D5.1.
If it is working, go to point 7.
Otherwise, replace it with a new one.
If off, go to point 3.
If shown, check the suction relay C paragraph
D5.1 and its wiring.
If still intact go to point 4.
Check the suction motor actuator, see the wiring
diagram.
Otherwise replace the instrument panel board, C4.2
Replace the instrument panel board.
The solenoid valve opens, go to point 2.
5
4
6
Check the motor carbon brushes and wiring.
3
Check the voltage reaches the coil and the drive
relay power contact, see chapter C3.
Check operation of the brush actuator
microswitch, see paragraph D 2.1.
3
2
Check that the solenoid valve is working
correctly, power it at 24 V. Check that there is a
voltage of 24 V at the ends of the solenoid valve
wires.
Check the connections under the instrument
panel, see paragraph C 4.2, C 4.3.
1
Check the error codes on the instrument panel
board display, see chapter E 1.1.
E2.1.6 The machine doesn’t move forwards
Replace the instrument panel board, see
paragraph C 4.2, C 4.3.
If the output voltage is not 24 V, check the wiring,
replace the instrument panel board.
Check that the filter is not blocked, see
paragraph B3.1.
If the connections are OK, go to point 3
Otherwise restore the connections.
If blocked, clean it and reassemble.
If not blocked go to point 4.
Otherwise adjust it or replace it.
If there is no voltage go to point 6.
Replace the carbon brushes or restore the wiring.
If everything is OK, go to point 6.
If there is voltage, go to point 5.
If the microswitch is working, go to point 4.
If no codes are shown, go to point 2.
If a code is shown, check which one.
If the checks on the solenoid valve are positive,
check the wiring output voltage.
E2.1.5 No water is released
8
Check connections to the instrument panel.
Instrument panel board, chapter C1.
1
Check that all the LEDs on the instrument panel
come on and that the solenoid valve opens.
6
If everything is OK go to point 8.
Check the carbon brushes or the motor, chapters A
7
Check the motor carbon brushes or replace the
brush motor, see chapter B1.
4
E2.1.4 The suction motor isn’t working
3
If not shown go to point 2.
1
67 of 68