PLDC04452
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
1
Move the machine onto flat and dry flooring.
2
Press the emergency switch (Traction) or switches into position "0" (Pad Assist).
3
Lift and turn the top dirty water tank.
4
Isolate and disconnect the power connector
A
to the suction motor, see Figure 23.
5
Remove the white plastic clamp
B
that fastens the cable to the suction motor plate.
6
Unscrew the two M6 screw
C
that fasten the suction unit motor to the dirty water tank.
7
Remove the suction motor from its compartment.
8
Check that the area inside the circle and the suction motor gasket
D
are not moist or wet, a sign
of liquid being drawn in that may damage the bearings inside the suction motor,
causing a louder metallic noise than normal.
Dismantling
B1.3 Replacing the suction motor
Fig. 24
D
A
B
C
Fig. 23
C
17 of 68