PLDC04452
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
1
Empty the solution tank and the dirty water tank.
2
Move the machine onto flat dry and smooth flooring.
3
Press the emergency switch (Traction) or switches into position "0" (Pad Assist).
4
Make sure that the batteries on the machine are charged.
5
Use a clamp-on ammeter with an end scale reading of at least 200 amperes, as shown in Figure 2.
6
Remove the power board.
7
Move the speed knob on the instrument panel to zero, turning it anticlockwise.
8
Remove the brush.
9
Switch the ammeter to
amperes
and
DC
A1.1 Cheking brush motor current input
Checks
Fig. 2
3 of 68