1
Move the machine to the tank draining area, and empty the solution tank and the dirty water tank.
2
Dismantle the solution tank as described in paragraph A1.2
3
Disconnect the power
A
and thermal
B
of the brush motor.
4
Remove the metal clamp
C
from the solution hose, and remove the hose
D
from the fitting on the motor.
5
Lay the machine on its side.
6
Unscrew the seven M6 x 12 mm stainless steel bolts
E
that fasten the reduction drive to the plate.
7
Remove the brush motor from the gearmotor support plate.
8
Take the reduction drive to the bench, and then remove the drive
D
, unscrewing it clockwise.
9
Replace the reduction drive with a new one.
A2.1 Replacing the brush motor
Dismantling
A
A
A
B
C
C
Fig. 12
10 of 68