36
Limitation of alarms (auto zone shutdown):
Maximum number of alarms per zone
(1 to 100pcs): in this section you can configure the
maximum number of alarms (activation events) to be accepted from one input. This makes it
possible to avoid a faulty detector connected to an input to generate alarms and notifications
continuously. If the number of alarm events generated by an input reaches the value configured
here, the given input will become restricted and the device will ignore further activation events of
the given input.
If the arming/disarming settings are not configured to “
Always armed
”, disarming and rearming
the device will re-enable the restricted input, then alarm events will be accepted again from the
given input, but again only the number of alarm events configured. If the arming/disarming settings
are configured to “
Always armed
”, or the “
24h zone
” option is enabled for the given input, the
restricted input will be re-
enabled automatically when the time configured at the “
Duration of
limitation
” option expires. The restriction only applies to inputs for which the
“
Auto shutdown
” option is enabled.
Duration of limitation
(1 to 24h): in this section you can configure how long the device should
ignore an input which has reached the limitation value entered at "
Maximum number of alarms
per zone
" option. When this period of time expires, the alarm counter will be reset automatically
and the input will be enabled again. This setting only applies to inputs for which both the
“
Auto shutdown
” and “
24h zone
” option is enabled, or to any input for which the
“
Auto shutdown
” option is enabled, if the arming/disarming settings are configured to
„
Always armed
”.
Cloud server:
Cloud usage
: if this option is enabled, the device will connect to the cloud server operated by the
manufacturer and will stay connected permanently. In order to ensure a continuous connection
and availability, the device sends supervision messages that use about
12 MB data per month
on its own. Using the cloud server, special services become available, such as remote
programming, control and monitoring of your device over the cloud. If this option is enabled, the
device will always be online and thereby accessible anytime. If this option is disabled, you can still
initiate a temporary cloud connection manually, by sending a command via SMS to the phone
number of the device. You can read more about this in the “
Remote connecting to devices via
paragraph.
In
case
of
using
a
SIM
card
that
uses
a private APN, the given private APN should be opened at the mobile service provider to access
the cloud server IP address at 54.75.242.103, port: 2020.
The cloud usage cannot be disabled in the
WiFi
product model.
Server
: you can select the default cloud server in this drop-down menu. If you are using the device
in in a private network, where there is no option to enable access to the cloud server, the program
offers an option to add custom cloud contact
details in the “
Server register
” menu. This can be
an IP address and port number available in the given private network, which you can then select
as the default cloud server in this drop-down menu. Thus, it is not necessary to enable access to
the cloud server in the private network, just configure port forwarding from the chosen IP address
and port number to the cloud IP address and port number (
54.75.242.103:2020
).