The following table gives an overview of V_RTC minimum voltage level requirements in order to keep RTC
running:
condition
minimum V_RTC [V]
min
Typ
max
room temperature
0.8
1.1
-40 to +125deg
0.9
1.2
So typically at room temperature a voltage difference of 2.3V
–
0.8V = 1.5V is available for buffering the
RTC supply in case V_BAT is removed.
An external capacitor for RTC buffering can be added, typical 100uF, up to maximum 220uF directly to the
LGA pin V_RTC.
In case an extreme large (super) capacitor, typical 1 F, is applied, a series resistor of typical 470 Ohm should
be added.
Typical current drawn from V_RTC by the RTC clock: 2.6
µ
A
An RTC alarm is one of the possible events to power ON the module.