74
Table 2- 21 Math Function Menu Description
Function
Menu
Settings
Description
Statistics
Reading statistic functions, including: max, min,
average, span, std dev and samples.
Limits
The Limits function performs Pass/Fail testing
according to the specified upper and lower limits.
dBm
The dBm is based on a calculation of power
delivered to a reference resistance, 0dBm = 1mW.
dB
The dB measurement is the difference between the
input signal and a stored relative value.
Rel Value Value/Off
Turn on the relative value function and set up the
value. Or turn off the function.
Explanations:
●
Math function can only be applicable to the main display.
●
If the measurement function has changed, all math functions will be
closed except Statistics.