![Teledyne T3DMM4-5 User Manual Download Page 106](http://html.mh-extra.com/html/teledyne/t3dmm4-5/t3dmm4-5_user-manual_1080739106.webp)
104
Loading Errors (AC Voltage)
In the AC Voltage function, the input of T3DMM4-5 appears as a 1MΩ resistance
in parallel with 100pF of capacitance. The test lead that you use to connect
signals to the Multimeter will also add additional capacitance and loading. The
approximate input resistances of the Multimeter at different frequencies are listed
in the following table.
Table 4- 2 Approximate Input Resistances at Different Frequencies
Input Frequency
Input Resistance
100Hz
1MΩ
1kHz
850kΩ
10kHz
160kΩ
100kHz
16kΩ
For low frequencies:
Error
(
%
)
=
×100%
For high frequencies:
Error
(
%
)
= [
-1] ×100%
F
: input frequency
R
s
: source resistance
C
m
: input capacitance (100pF) plus test lead capacitance