Configuring the VM700T Video Measurement Set
VM700T Option 01 (NTSC) & Option 11 (PAL) User Manual
2- 27
H
Parity
: can be set to None, Odd, Even, Zero, or One.
H
Reset Character
: can be set to None or Ctrl-A through Ctrl-Z. (Note: the
Reset Character for an Apple LaserWriter is Ctrl-D.)
H
Carrier Detect
: can be enabled or disabled.
The default Port 1 settings are suitable for a serial Epson LQ-570 printer.
To Change a Port Configuration Parameter Value:
1.
Select the parameter you wish to change by rotating the knob until the
parameter is highlighted, then touching the screen over the parameter value.
A box appears around the item to edit.
2.
Rotate the control knob until the desired parameter value appears in the edit
box.
3.
Either press the
Accept Input
soft key or touch the screen anywhere inside
the window.
4.
Press the
Update & Exit
soft key to save the changes.
When high-level diagnostics are run, any errors detected are written to the
Diagnostic Errors file. The contents of this file can be printed using the Print File
soft key, or the file can be deleted using the Delete soft key.
If diagnostic errors appear, refer to the servicing information found in the
VM700T Video Measurement Set Service Manual
.
The maximum capacity for the Diagnostic Errors file is 100 lines in a circular
file (scrolling past the last entry returns to the top line of the file). If the number
of errors detected causes the file to exceed this length, the earlier results are
scrolled out of the file buffer. When this occurs, the Diagnostic Errors file
includes a message stating that some of the text has been scrolled out of the file.
The Diagnostics Selection file lists the diagnostics the measurement set can
perform at power on. If installed options require additional diagnostics, those are
also listed. As received from the factory, all diagnostics are selected, but
bypassed by default for a quick startup. Refer to
Setting the Power Up Mode
on
page 1--9 for information on reconfiguring the measurement set to run diagnos-
tics at power on. Any diagnostic can be deselected by rotating the control knob
until the diagnostic is highlighted (see Figure 2--11, then touching the right side
of the highlighted line (above the words Not Selected). To return the choice to
selected, highlight the choice and touch the screen on the left side (above the
word Selected).
Diagnostic Errors (File)
Diagnostics Selection
(File)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for VM700T
Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 17: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 37: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 75: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 107: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 131: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...