Programming
Table
3-1
(cont)
ERROR QUERY AND STATUS INFORMATION
(Bus Reportable)
EXECUTION ERRORS (200) (cont)
Error
Error Type/Message
Priority
282
Delay out of range
03
283
W + D > 0.85 P
03
284
P - (W + D) < = 40 ns
03
285
D < = W
03
286
D
< =
W
+
NI
03
290
Synt illegal data
03
INTERNAL ERRORS {300)
SRQ byte 99 or 115 (busy bit set)
Error
Error Type/Message
Priority
340
Save RAM failure
05
350
Synthesizer out of lock
05
PFG 51 05/5505 Instruction Manual
Description
This error will be returned if the delay is set greater
than the period and the mode is set to continuous
or burst mode.
This error is returned if width + delay > 0.85 x
period (single or double pulse).
This error is returned if period > width + delay +
40 ns (single or double pulse).
This error is returned if delay =::width (double pulse
only).
This error is returned if delay =::width + NI (double
pulse only).
Width Range
D-W > NI
0.40 - 0.099 !:,lS
40 ns
0 .. 1 00 -0.999 !:,lS
50 ns
1 .00 - 9.99 !:!:.S
200 ns
1 0.0 - 99.9 !:,lS
2.0 /lS
1 00 - 999 !:,lS
20 /lS
1.00 - 9.99 ms
200 us
10.0 - 99.9 ms
2.0 ms
Frequency out pf range of the synthesizer.
Description
If the checksum of the Save RAM is bad, this error
will be returned.
This error will be returned if the synthesizer is not
locked. An internal error is returned by a serial poll.
3-33