![Tektronix PFG 5105 Instruction Manual Download Page 28](http://html1.mh-extra.com/html/tektronix/pfg-5105/pfg-5105_instruction-manual_1077779028.webp)
Section
2
OPERATING INSTRUCTIONS
Introduction
This section of the manual provides installation and
removal instructions and describes the functions of
the PFG 51 05/5505 front-panel controls and connec
tors. This information is provided as an aid in under
standing how to operate the PFG 51 05/5505 under
local (manual) control only. The information in this
section assumes the instrument is not connected to
the GPIB. Complete information for programming the
PFG 51 05/5505 via the GPIB (General Purpose Inter
face Bus) is found in the Programming section of this
manual.
PREPARATION FOR USE
Installation and Removal -PFG 51 05 Only
NOTE
The PFG 5 105 is designed to operate only in
a
TM 5000-Series power module. Refer to the
power module instruction manual before install
ing the PFG 5105.
The PFG 51 05 is calibrated and ready for use when
received. It operates in three compartments of any
TM 5000-Series GPIB compatible power module. Refer
to the power module instruction manual for line
voltage requirements. and power module operation.
�
To prevent damage to the PFG 5105, turn the
power module off before installation or removal.
Do not use excessive force to install or remove.
Check to see that the plastic barriers on the inter
connecting jacks of the selected power module com
partments match the cutouts in the PFG 5105 circuit
board edge connectors. If these do not match, do
PFG 51 05/5505 Instruction Manual
not insert the instrument until the reason is deter
mined. When the units are properly matched, align
the PFG 51 05 chassis with the upper and lower guides
of the selected compartments. Insert the PFG 51 05
into the power module and press firmly to seat the
circuit board edge connectors in the power module
interconnecting jacks. Apply power to the PFG 51 05
by actuating the power switch on the power module.
To remove the PFG 5105 from the power module,
pull both release latches on the front panel until the
interconnecting jack disengages. The instrument will
then slide straight out.
Power Cords -PFG 5505 Only
The PFG 5505 is shipped with the power cord option
as ordered by the customer (see Fig. 2-1 ). Verify that
the instrument power cord is the proper cord for use
with the available power.
PLUG
LINE
REFERENCE
OPTION
CONFIGURATION
USAGE
VOLTAGE
STANDARDS
NUMBER
�
North
ANSI C73. 1 1
American
1 20V
NENA 5-1 5-P
=---
'
1 20/1 SA
IEC 83
�
Universal
CEE (?).II.IV.VII
Euro
240V
A1
240V/
IEC 83
1 0-1 6A
�
UK
BS 1 363
240V/
240V
IEC 83
A2
1 3A
�
Australian
AS C1 1 2
240V/
240V
A3
1 0A
�
North
ANSI C73.20
American
240V
NEMA 6-1 5-P
A4
240V/
IEC 83
,,
1 5A
�
Switzerland
SEV
220V/
220V
AS
6A
Fig. 2-1 . Power Cords.
6759-13
2-1