![Tektronix PFG 5105 Instruction Manual Download Page 55](http://html1.mh-extra.com/html/tektronix/pfg-5105/pfg-5105_instruction-manual_1077779055.webp)
Programming
DT (Device Trigger)
Command Type:
Setting or query
Setting Syntax:
DT TRIG
DT GATE
DT SET
DT OFF
Query Syntax:
DT?
Query Response (one of the following):
DT TRIG;
DT GATE;
DT SET;
DT OFF;
Discussion:
T his command controls the instrument's response
to the Group Execute Trigger < GET > interface
message.
When a < GET > interface message is received and
the OT TRIG mode is set, the instrument produces
one cycle of signal if it is in TRIG mode, or it produces
a burst of cycles if it is in BURST mode.
If the trigger mode is set to GATE and < GET > is
received, the output is turned on until < GET > is
received again.
T he SET argument causes the instrument to wait for
a < GET > interface message before updating its
settings.
The power-on setting is DT OFF; the instrument
updates its settings without ·waiting for < GET > .
If DT is off and < GET > is sent, the error message:
206, "GET IGNORED"; will be returned.
3-1 0
ERROR? o r EVENT?
Command Type:
Query
Query Syntax:
ERRor?
EVENT?
Examples:
ERR?
ERROR?
EVENT?
Query Response: (depends on query sent)
ERR < num > ;
EVENT < num > ;
Discussion:
T his que
r
y returns the error code for the last SRQ
that was polled (with RQS ON), or it returns the error
code for the oldest error in the error queue if ROS
is OFF. Error code O (nothing to report) is returned
if the error queue is empty.
PFG 51 05/5505 Instruction Manual