Analyze Waveform or Trace Data
7.
Push
Select
.
This makes the vertical cursors active and
the horizontal cursors inactive. Now, as you
turn the multipurpose knobs, the vertical
cursors will move.
Push
Select
to make the horizontal cursors
active again.
8.
View the cursor and the cursor readout.
NOTE.
On digital channels, you can take timing
measurements with cursors, but not amplitude
measurements.
9.
Display multiple waveforms on the screen
by pushing one or more of the channel
1
through
4
buttons or by pushing the
D15 –
D0
button.
10.
Push and hold
Cursors
to display the cursor
menu again.
11.
Push
Source
from the lower-bezel menu.
A pop-up menu will appear. The default
menu selection of
Selected Waveform
will
cause the cursors to take measurements on
the selected (last used) waveform.
12.
Turn multipurpose knob
a
to choose a
channel to measure other than the one
pointed to by
Selected Waveform
.
13.
Push
Menu Off
to remove the pop-up menu.
14.
Turn multipurpose knob
a
and take cursor
measurements on the alternate waveform.
MDO4000 Series Oscilloscopes User Manual
131
Summary of Contents for MDO4054-3
Page 2: ...x MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual P071291300 071 2913 00...
Page 3: ......
Page 4: ...MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tektronix com 071 2913 00...
Page 11: ...Table of Contents iv MDO4000 Series Oscilloscopes User Manual...
Page 19: ...Preface xii MDO4000 Series Oscilloscopes User Manual...