Display Waveform or Trace Data
5.
Average: Averages all points in each
interval.
6.
-Peak: Uses the lowest amplitude point
in each interval.
RF Time Domain Traces
The time domain window can also display three RF time domain traces, in addition to the usual analog and digital
waveforms. You may turn each of these traces on or off independently, and display all or some of them simultaneously.
To use these traces:
1.
Push
RF Versus Time Traces
from the RF
Menu to bring up the related side menu.
RF Versus
Time
Traces
2.
Set
Amplitude
to
On
to display the
amplitude versus time trace.
Amplitude
On|
Off
3.
Set
Frequency
to
On
to display the
frequency versus time trace.
Frequency
On|
Off
4.
Set
Phase
to
On
to display the phase versus
time trace.
Phase
On|
Off
5.
Set
Freq/Phase Squelch
to
On
to use the
squelch feature.
Freq/Phase
Squelch
On|
Off
6.
Push
Squelch Threshold
and rotate
multipurpose knob
a
to set the threshold for
the squelch feature.
Squelch
Threshold
(a)22.3
μ
V
The trace options are:
MDO4000 Series Oscilloscopes User Manual
113
Summary of Contents for MDO4054-3
Page 2: ...x MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual P071291300 071 2913 00...
Page 3: ......
Page 4: ...MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tektronix com 071 2913 00...
Page 11: ...Table of Contents iv MDO4000 Series Oscilloscopes User Manual...
Page 19: ...Preface xii MDO4000 Series Oscilloscopes User Manual...