Operating basics
Arbitrary Waveform Edit
Example 1
The following example shows how to use the Line edit function. Paste a ramp
waveform before sine waveform:
1.
Select Number of
Points to set the
number of waveform
points to 1000 points.
2.
Select New and then
select Sine. Save this
waveform to User1.
3.
Next, create a 500
point ramp waveform.
4.
Select Operation and
select Line. Do the
following line edit:
X1: 1, Y1: 8191
X2: 250, Y2: 16382
Push Execute. Once
again, select Line from
Operation and perform
the following line edit:
X1: 251, Y1: 16382
X2: 500, Y2: 8191
5.
Push Execute. Save
this waveform to
User2.
6.
Next, paste a
waveform. Push Read
from... and select
User1.
7.
Push Paste at
Beginning. Select
User2 waveform and
then select Paste.
8.
The waveform shown
here is created.