Calibration—7623/R7623
Service
FAST
STORAGE
MODE
Equipment
Required
4. Five-nanosecond G
R cable
1. 7B53A Horizontal time-base plug-in
unit
5.
50-ohm GR
in line termination
2.
7A15A Vertical
Amplifier plug-in unit
6.
Test-oscilloscope with
10X probe
3.
Medium-frequency
constant-amplitude signal generator
7.
Three-inch screwdriver
Control
Settings
Set
the
controls as given in
the Preliminary Control
Settings.
44.
Check-Fast
Storage Mode
a.
Install
the vertical
amplifier unit in the left vertical
compartment.
b.
Install
the
horizontal time-base
plug-in unit in the
horizontal compartment.
c.
Set
the
horizontal
time-base
unit to
single sweep.
d. Connect the
medium-frequency generator to
the left
vertical
amplifier
plug-in unit.
e. Set the frequency of the medium-frequency generator
to five megahertz
at
3.2
divisions of vertical deflection.
f. Press the
FAST button.
g.
Press
the
ER ASE button.
h.
Press the single
sweep
reset
button on the hori
zontal time-base plug-in
unit. A stored display should be
visible.
i. CHECK—Storage
test points (see Fig. 2-10). Table 2-6
lists the storage
test points and
their
voltage tolerances.
Connect the test
oscilloscope
10X probe to each storage
test
point, in turn, setting the test oscilloscope
vertical
deflection factor to
1.0 V, 2.0 V, and 5.0 V as required.
TABLE
2-6
Test
Points
Tolerance
High Speed Mesh
+120 V to +130
V
Collector
+144 V to +156 V
ce
3
+81.6 V to +88.4 V
ce
2
+81.6 V
to +88.4 V
CE
1
+43.2 V to +46.8 V
FGA
+34.5 V to +37.4 V
FGK
Less
than
500 mV
j.
Disconnect the vertical plug-in units input signal.
k.
Press
the ERASE button (do not reset sweep
or
transfer
the display to the viewing screen).
l. CHECK—Storage
test points (see Fig. 2-10). Table 2-7
lists
the storage test points and their voltage tolerances.
Connect
the test oscilloscope 10X probe to each storage
test
point,
in turn, setting
the test oscilloscope vertical
deflection
factor to 1.0 V, 2.0 V,
and 5.0 V as required.
TABLE
2-7
Test Points
Tolerance
Collector
+122
V
to +133 V
ce
3
+75 V to +85 V
CE
2
+30 V to +80 V
CE,
+28
V
to
+32 V
FGA
+19
Vto +21 V
FGK
Less than
500 mV
2-29
Summary of Contents for 7623
Page 1: ...MANUAL 7623 R7623 STORAGE OSCILLOSCOPE SERVICE MANUFACTURERS OF CATHODE RAY OSCILLOSCOPES ...
Page 51: ...Fig 3 2 Block diagram of Logic circuit Circuit Description 7623 R 7623 Service ...
Page 72: ...W NJ 00 Fifl 3 22 Low Voltage Power Supply detailed block diagram ...
Page 73: ...Circuit Description 7623 R 7623 Service ...
Page 74: ...CO NJ CD Fig 3 22 Low Voltage Power Supply detailed block diagram cont ...
Page 75: ...Circuit Description 7623 R 7623 Service ...
Page 97: ...Circuit Description 7623 R7623 Service 3 51 ...
Page 98: ...Circuit Description 7623 R7623 Service Fig 3 39 Output Pulses for the Storage Circuits 3 52 ...
Page 103: ...Circuit Description 7623 R7623 Service 3 57 ...
Page 108: ... Ç À Fig 4 2 Location of circuit boards in the 7623 ...
Page 109: ...Fig 4 3 Location of circuit boards in the R7623 Maintenance 7623 R 7623 Service ...
Page 113: ...Maintenance 7623 R7623 Service Fig 4 6 Circuit Isolation Troubleshooting Chart 4 9 ...
Page 165: ...7623 BLOCK DIAGRAM ...
Page 166: ...7623 R7623 Service Front of Board ...
Page 167: ......
Page 168: ...FL ...
Page 169: ......
Page 173: ...7623 Logic ...
Page 175: ...Vertical Interface A4 ...
Page 178: ...Vertical Interface ...
Page 180: ...Vertical Amp A5 ...
Page 184: ...Horizontal Amp A6 ...
Page 186: ...7623 TO P450 VERT AMP 3 HORIZONTAL AMPLIFIER ...
Page 188: ...Output Signals A7 ...
Page 190: ...FROM 7G23 Output Signals g ...
Page 195: ...FROM LV POWER SUPPLY 7623 CRT CIRCUIT ...
Page 197: ......
Page 200: ......
Page 202: ...Storage Output A14 ...
Page 204: ......
Page 205: ...7623 R7623 Service Fig 6 14 A15 Cal Storage circuit board ...
Page 208: ......
Page 209: ...7623 R7623 Service Fig 6 15 A16 Readout System circuit board ...
Page 213: ......
Page 242: ...7623 R7623 OSCILLOSCOPE b ...
Page 243: ...151 ...
Page 246: ...20 ...
Page 247: ...7623 R7623 OSCILLOSCOPE 112 ...