Section
2—7623/R7623
Service
CALIBRATION
Calibration
Interval
To
assure instrument accuracy, check the calibration of
the
7623 every 1000 hours of operation,
or every six
months if used
infrequently.
Before complete calibration,
thoroughly
clean and inspect
this
instrument as outlined in
the
Maintenance section.
Tektronix
Field
Service
Tektronix,
Inc.
provides complete instrument repair and
recalibration
at local Field Service Centers and the Factory
Service
Center. Contact your
local Tektronix Field
Office
or representative for further information.
Using
This
Procedure
General.
This
section
provides several features
to facili
tate
calibration
of the
7623. These are:
Index.
An
index is given
preceding
the calibration
procedure
to aid
in
locating a step.
Performance
Check.
The performance
of this instrument
can
be checked by
performing only the VCHECK steps.
The
V preceding a
step indicates that performing this step
checks
the instrument against
the
tolerance listed
as
a
Performance
Requirement (see Specification Section in the
Operators Manual).
Partial
Procedure.
A
partial calibration is often desirable
after
replacing components, or to touch up the adjustment
of
a portion
of the instrument between
major recalibra
tions.
To
calibrate only part of the instrument, set the
controls
as given under Preliminary Control Settings and
start
with
the
nearest Equipment Required list preceding
the desired portion. To prevent
unnecessary recalibration
of
other
parts
of
the
instrument, re-adjust only if the tolerance
given
in the CHECK-
part of the step is not met.
If
re-adjustment
is
necessary, also check the calibration of
any
steps
listed
in
the
INTERACTION— part of the step.
Complete
Calibration
Procedure.
Completion
of each
step
in the following calibration procedure ensures that this
instrument
is
both correctly adjusted and performing
within all
given
tolerances.
TEST
EQUIPMENT
REQUIRED
The test equipment and
accessories, or the equivalent,
given
in
the Test Equipment table is required for complete
calibration
of the 7623. Specifications given for the test
equipment
are
the
minimum necessary for accurate calibra
tion.
Therefore, the specifications of any test equipment
used
must meet
or exceed
the listed specifications. All test
equipment
is
assumed to
be correctly calibrated and
operating within
the
listed specification. Detailed operating
instructions
for
the
test equipment are not given in this
procedure. Refer
to the instruction
manuals for the test
equipment
for
more information.
Special
Calibration
Fixtures
Special
Tektronix calibration fixtures are
used in this
procedure only where they facilitate instrument calibration.
These special calibration fixtures
are available from
Tektronix,
Inc. Order by
part number through your local
Tektronix
Field Office or representative.
Calibration
Equipment
Alternatives
All
of the listed test equipment is required to completely
check
and adjust this instrument. This calibration pro
cedure
is based on the first item of equipment given as an
example
of applicable equipment. When other equipment is
substituted,
control
settings
or calibration setup may need
to be
altered
slightly to meet the requirements of the
substitute equipment. If the
exact item
of
test equipment
given
as an example in the Test
Equipment table is not
available,
first check the Specifications column carefully to
see
if any
other equipment is available which might suffice.
Then
check the Usage column to see what this item of test
equipment
is
used for. If used for a check or adjustment
which is
of little or no importance to your measurement
requirements,
the
item
and corresponding step(s)
can be
deleted.
The
following procedure is written to completely check
and adjust
the 7623
to the limits given in Section 2 of the
Operators
Manual
and
to allow interchanging 7000-series
plug-in
units
between 7000-series mainframes without the
need
to recalibrate the instruments each time. If applica
tions for
which you will use the
7623 do not require the
full available performance
from the 7623 and plug-in units,
this procedure
and the
required equipment list can be
2-1
Summary of Contents for 7623
Page 1: ...MANUAL 7623 R7623 STORAGE OSCILLOSCOPE SERVICE MANUFACTURERS OF CATHODE RAY OSCILLOSCOPES ...
Page 51: ...Fig 3 2 Block diagram of Logic circuit Circuit Description 7623 R 7623 Service ...
Page 72: ...W NJ 00 Fifl 3 22 Low Voltage Power Supply detailed block diagram ...
Page 73: ...Circuit Description 7623 R 7623 Service ...
Page 74: ...CO NJ CD Fig 3 22 Low Voltage Power Supply detailed block diagram cont ...
Page 75: ...Circuit Description 7623 R 7623 Service ...
Page 97: ...Circuit Description 7623 R7623 Service 3 51 ...
Page 98: ...Circuit Description 7623 R7623 Service Fig 3 39 Output Pulses for the Storage Circuits 3 52 ...
Page 103: ...Circuit Description 7623 R7623 Service 3 57 ...
Page 108: ... Ç À Fig 4 2 Location of circuit boards in the 7623 ...
Page 109: ...Fig 4 3 Location of circuit boards in the R7623 Maintenance 7623 R 7623 Service ...
Page 113: ...Maintenance 7623 R7623 Service Fig 4 6 Circuit Isolation Troubleshooting Chart 4 9 ...
Page 165: ...7623 BLOCK DIAGRAM ...
Page 166: ...7623 R7623 Service Front of Board ...
Page 167: ......
Page 168: ...FL ...
Page 169: ......
Page 173: ...7623 Logic ...
Page 175: ...Vertical Interface A4 ...
Page 178: ...Vertical Interface ...
Page 180: ...Vertical Amp A5 ...
Page 184: ...Horizontal Amp A6 ...
Page 186: ...7623 TO P450 VERT AMP 3 HORIZONTAL AMPLIFIER ...
Page 188: ...Output Signals A7 ...
Page 190: ...FROM 7G23 Output Signals g ...
Page 195: ...FROM LV POWER SUPPLY 7623 CRT CIRCUIT ...
Page 197: ......
Page 200: ......
Page 202: ...Storage Output A14 ...
Page 204: ......
Page 205: ...7623 R7623 Service Fig 6 14 A15 Cal Storage circuit board ...
Page 208: ......
Page 209: ...7623 R7623 Service Fig 6 15 A16 Readout System circuit board ...
Page 213: ......
Page 242: ...7623 R7623 OSCILLOSCOPE b ...
Page 243: ...151 ...
Page 246: ...20 ...
Page 247: ...7623 R7623 OSCILLOSCOPE 112 ...