Alternative Procedure
Description
Amplifier high frequency peaking is adjusted so that
bandwidth is adequate
and lhat the aberrations are not excessive. This procedure is used when neither the
11401 nor the 11402 mainframe is available. Performance is assured only for the
particular plug-in and mainframe combination examined and adjusted in this
procedure.
Plug-in and mainframe aberrations are displayed at 20% per division.
Measurement Limits
The waveform aberrations should not exceed 4.5% peak (0.225 division) and 7%
(0.35 division) peak-to-peak. One major
division
20%.
Checks
Adjustments-IL432 Service Reference