background image

The Right Control For Your Application

THE BOILER CONTROL SPECIALIST

Four Stage Boiler Control 254

Power

Heat
Demand

WWSD

UnOcc.

Minimum

Stage 1

Occupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Unoccupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Stage 2

Pump

DHW
Demand

Stage 3

Stage 4

Eight Stage Boiler Control 258

Power

Heat
Demand

Minimum

WWSD

Pump

Stage 1

Stage 2

Comb. air

Stage 3

Stage 6

Stage 5

Stage 8

Stage 7

Stage 4

Menu

Item

Override

Setpoint

Actual
Supply

Target
Supply

S

PRGM

TEMP

F C

TIME

USE

AMPM

UNOCC

OVR

M T W T F S

OUTSIDE

ROOM

1
2

Four Stage Boiler

Control 254

Eight Stage Boiler

Control 258

And more to come!

Contact your wholesaler or

tekmar agent for information

on the newest additions

to the tekmar product line.

Sign up for a tekmar Control

Course or School and stay

up-to-date with our latest

control developments.

Limited Warranty and Product Return Procedure

Two Stage Boiler & DHW

Control 252

Two Stage Boiler & DHW Control 252

Power

Heat
Demand

WWSD

UnOcc.

Minimum

Stage 1

Occupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Unoccupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Stage 2

System
Pump

DHW
Demand

DHW
Pump

One Stage Boiler & DHW Control 251

Occupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Unoccupied

35 

(2)

105

(41)

70

°

F

(21

°

C)

Power

Heat Demand

DHW Demand

WWSD

Unoccupied

Min. Supply

Boiler 

One Stage Boiler & DHW

Control 251

UnOcc

Power

Minimum

One Stage Boiler 
Control 250

Boiler On

WWSD

One Stage Boiler

Control 250

Limited Warranty:  tekmar warrants to the original purchaser each tekmar product against defects

in workmanship and materials when the product is installed and used in compliance with tekmar's

instructions.  This limited warranty covers the cost of parts and labour provided by tekmar to correct

defects in materials and/or workmanship.  Returned products that are fully operational are not

considered a warranty case.  tekmar also does not cover parts or labour to remove, transport or

reinstall a defective product.  tekmar will not be liable for any damage other than repair or

replacement of the defective part or parts and such repair or replacement shall be deemed to be the

sole remedy from tekmar.  This warranty shall not apply to any defects caused or repairs required

as a result of unreasonable or negligent use, neglect, accident, improper installation, or unauthorised

repair or alterations.  In case of defect, malfunction or failure to conform to warranty, tekmar  will, for

a warranty period of 24 months from the date of invoice to the original purchaser or 12 months from

the date of installation of the product, whichever occurs first, repair, exchange or give credit for the

defective product.  Any express or implied warranty which the purchaser may have, including

merchantability and fitness for a particular purpose, shall not extend beyond 24 months from the date

of invoice or 12 months from the date of installation of the product, whichever occurs first.

Replacements: tekmar can send replacement products if requested.  All replacements are invoiced.

Any possible credit for the replacement will only be issued once the replaced product has been

returned to tekmar.

Product Return Procedure:  Products that are believed to have failed must be returned to tekmar

Control Systems Ltd. 4611-23rd Street, Vernon B.C. Canada V1T 4K7 when agreed to by  tekmar.  The

installer or other qualified service person must, at the owner's expense, determine which component

has failed.  The product must be returned complete with all of its components (sensors, base, etc.).

Products must be returned together with the proof of purchase to the original purchaser who then returns

the product to tekmar after receiving a Return Goods Authorisation (RGA) number from tekmar.

Please include the following information with the product:  The full address of the original purchaser,

the RGA number and a description of the problem.

From the U.S.A., in order to avoid customs charges, products must be returned via US Post with the

package clearly marked with the RGA number, product type and the statement "Canadian Product

returned for repair".  For shipping purposes the product can be valued at one half list price.

1)

If returned during the warranty period and the product is defective, tekmar will issue full credit

 for the returned product less cost of missing parts.

2)

If returned during the warranty period and the product is fully operational, tekmar will return the

product to the original purchaser for a testing cost of $30.00 plus postage.

3)

If returned during the warranty period and the product is not damaged and is fully operational,

tekmar can take back the product for a return charge of 40% of the product's net value.  This

request has to be specified otherwise the product will be returned with a testing cost of $30.00

plus postage.

4)

If returned after the warranty period and the product needs repair, tekmar will repair and return

the product.  Repair and postage costs will be invoiced.  tekmar's repair costs are calculated

at $30.00 / hour plus the cost of parts.  If the repair costs will be more than $60.00 a repair

estimate will be sent to the original purchaser.

In North America:

tekmar Control Systems Ltd ., Canada
tekmar Control Systems,  Inc., USA
Head office: 5100 Silver Star Road
Vernon, B.C. Canada V1B 3K4
Tel.  (250) 545-7749   Fax.  (250) 545-0650

All specifications are subject to change without notice.

Printed in Canada on recycled paper.

Product design, software and literature are Copyright © 1993 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.

Printed in Canada on recycled paper by

Wayside Press Ltd. Vernon / Kelowna, B.C.

20

Summary of Contents for Eight Stage Boiler Control 258

Page 1: ...mand Minimum WWSD Pump Stage 1 Stage 2 Comb air Stage 3 Stage 6 Stage 5 Stage 8 Stage 7 Stage 4 Menu Item Override Setpoint Actual Supply Target Supply S PRGM TEMP F C TIME USE AMPM UNOCC OVR M T W T...

Page 2: ...ugh water to keep the room temperature warm particularly during the colder weather If the Heating Curve selected is too high the supply water will be too hot for the conditions and the building will o...

Page 3: ...ntrol The effect of the Integral function can also be easily viewed by not allowing a rise in supply temperature when the control asks for more heat The displayed target temperature will show a slow b...

Page 4: ...allow Heating Curve operation System pump light on the system pump relay is on closing the contacts between terminals System Pmp 3 4 Comb air light on the combustion air relay is on closing the contac...

Page 5: ...e Occupied room temperature setting the control enters WWSD When switched into Unoccupied mode the UNOCC display element will replace the OCC display element and the control will switch from operating...

Page 6: ...e Stage and Comb air lights will be shut off with the boilers and combustion air damper The control will continue to cycle the boilers and combustion air damper to maintain the supply at the target te...

Page 7: ...lighter guage wire is too fragile and may also contribute too much resistance to the circuit Power should not be applied to any of the wires during this rough in wiring stage Step Four Electrical con...

Page 8: ...nals Heat Dem 5 and 6 When 24Vac is applied to these terminals the control will recognize a call for heat from the system DIP switch must be set to Reset If a 24Vac Setpoint Demand signal is used aqua...

Page 9: ...powered up the combustion air damper should operate If it does not come on check the circuit wiring for errors and ensure that it is powered up and the voltage is correct Check the devices in the cir...

Page 10: ...e Heating Curve use the following formula Outdoor air temperature Supply water temperature 50 10 30 1 10 12 10 F 23 C 110 43 70 21 70 21 90 32 210 99 170 77 150 65 130 54 190 88 3 6 3 0 2 4 2 0 1 6 0...

Page 11: ...w Domestic Hot Water boilers to be switched over to assist the heating boilers during peak load times Int timer switch The 258 control has an internal timer programmed using the LCD display and keypad...

Page 12: ...tback and delivering cold water to the boilers increased load Typically this will cause many or all of the boilers to be staged on with minimum delay which is the correct control action for the situat...

Page 13: ...ustion air damper will remain open After the 5 minutes the control will automatically exit the test routine and enter the normal operating mode If there is no Heat Demand the control will not allow a...

Page 14: ...ply temperatures and the LED system status lights display the operation of the various system components A competent troubleshooter can locate system faults without having to go any further than obser...

Page 15: ...tual Supply Target Supply F S TEMP OCC S M W T F T Auto Stage 1 2 3 4 5 6 7 8 Perm Demand Ext timer Fixed last Int timer Lo Hi fire Fixed lead Rotate Off 1 2 3 4 5 6 7 8 9 External Demand Off 1 2 3 4...

Page 16: ...ress or to change the day pointer PROGRAM MENU VIEWING Must be set to Int timer Auto 1 2 3 4 5 6 7 8 Perm Demand Ext timer Int timer Off 1 2 3 4 5 6 7 8 9 External Demand Off 1 2 3 4 5 6 Stpnt Reset P...

Page 17: ...button when the control is showing a fixed display Setpoint Actual Supply Target Supply F S TEMP S M W T F T OVR UNOCC Which mode is selected See page 3 Menu Item Override Menu Item Override Menu Item...

Page 18: ...nOcc 1 5 00 pm Occ 2 10 30 pm UnOcc 2 Friday 6 00 am Occ 1 8 30 am UnOcc 1 5 00 pm Occ 2 11 30 pm UnOcc 2 Saturday 8 00 am Occ 1 11 30 pm UnOcc 1 Null Occ 2 Null UnOcc 2 Schedule P 5 Day Time Temperat...

Page 19: ...when powered down for up to 10 years Battery backup Maintains clock operation for 24hrs when powered down Dial Switch Settings Heating Curve 0 4 to 3 6 Minimum Off 80 to 170 F Off 27 to 77 C Boiler D...

Page 20: ...antability and fitness for a particular purpose shall not extend beyond 24 months from the date of invoice or 12 months from the date of installation of the product whichever occurs first Replacements...

Reviews: