5
98-01467-EN R1
Radion 8140 automatic sprayer control
3) SET UP THE MACHINE
Machine configures machine settings. Options include Filling,
Operation, Implement parameters, Calibrations and Alarms.
1.
From the Home screen, press the SETTINGS button
.
2. Press
Machine
.
3. Select from:
►Filling – establishes the amount of actual and desired material
in the tank and the density of that material
►Operation – establishes application rate step, speed source,
simulated speed and minimum speed
►Implement parameters
◄ Section configuration – sets the number of nozzles on
the boom which determines the spraying width during
application
◄ Nozzle preset setup – establishes options for up to five (5)
nozzles including series, capacity, low/high pressure limits,
reference flow and reference pressure
◄ Regulation parameters – adjusts valve calibration and
nozzle spacing and selects a regulation mode
►Calibrations – establishes either manual/automatic settings
of the Implement speed sensor, Flow sensor, Liquid pressure
sensor, Fill flow sensor and Tank level sensor
►Alarms – establishes alarms on/off and sets their trigger levels
4. Press RETURN arrow to return to the main Settings screen.
Figure 9: Machine
Operation
1.
From the Home screen, press the SETTINGS button
.
2. Press
Machine
.
3. Press
Operation
.
4. Press setting value to adjust settings as needed:
◄Application rate step – the percent of increase/decrease boost
of the active application rate at which the product is applied
◄Speed source – selects whether to base the machine speed
on input from the CAN , an Implement or a Simulated
source
◄Simulated speed – establishes a speed for using the
Simulated speed source
◄Minimum speed – establishes the minimum forward speed at
which the system should automatically switch the main valve
off
5. Press RETURN arrow to return to the Machine screen.
Figure 10: Operation
Figure 11: Application rate step on Operation screen
0%
Man
reg
5%
5%