Radion 8140 automatic sprayer control

 Maximum pressure

Liquid pressure sensor

->Maximum pressure establishes the 

maximum allowed pressure limit for the liquid pressure sensor. 

The automatic calibration is based on the recommended maximum 

pressure level and a tested reference pressure level.

►Maximum pressure – enter the maximum allowed pressure 

limit for the liquid pressure sensor. Use Automatic calibration 

to calculate the maximum pressure automatically. 

►Reference pressure – enter the pressure value used as 

reference for the actual liquid pressure sensor calibration. 

The reference pressure can be changed, but not while in the 

calibration mode. 

►Automatic calibration – if the maximum pressure is not known, 

or to make sure the value is correct, automatic calibration 

establishes the calibration. 

►Complete calibration – apply constant reference pressure to 

the sensor. Press “Done” when complete.

►Master switch status / Pressure adjustment – 

  Shows if the Master switch is off   or on  . 
  Press the UP/DOWN arrows      to increase/decrease 

the pressure until reaching and maintaining the reference 

pressure.

►Minimum/maximum pressure bar – illustrates the change in 

pressure from minimum to maximum. 

Figure 24: Liquid pressure sensor->Maximum pressure

Maximum pressure automatic calibration

IMPORTANT: Make sure all section valves are open before opening 

the Master valve; otherwise, the pressure could build and 

damage the system.

1. Press the Reference pressure value 

2. Enter the pressure value used as reference for the actual liquid 

pressure sensor calibration.

3. Press 

 Calibrate 

 

 to start an automatic calibration of the sensor.

4. Turn on Master switch 

.

5. Press the UP/DOWN arrows      

 to increase/decrease the 

pressure until reaching and maintaining the reference pressure.

6. Apply constant reference pressure to the sensor.
7. Press 

 Done 

 

 when complete.

8. Turn off Master switch 

 to stop calibration.

To cancel the calibration, press the RETURN arrow 

 or the Home 

button 

.

Figure 25: Automatic maximum pressure


Summary of Contents for RADION 8140

Page 1: ...U S E R G U I D E RADION 8140 Automatic sprayer control Software version 1 05...

Page 2: ...uto steering device is not designed to replace the vehicle s operator Do not leave a vehicle while the Radion 8140 is engaged Ensure the area around the vehicle is clear of people and obstacles before...

Page 3: ...t application rates 4 3 SET UP THE MACHINE 5 Operation 5 Implement parameters 6 Section configuration 6 Nozzle preset setup 6 Establish nozzle presets 7 Calibrations 7 NO 4 START NEW JOB OR CONTINUE J...

Page 4: ...et com Radion 8140 automatic sprayer control NOZZLE SELECTION 20 Selecting the current nozzle 20 Presetting nozzles 20 TANK 21 ALARM WARNING 21 PRESSURE GAUGE 22 BOOM SECTIONS SWITCHES 22 ALARM CONFIG...

Page 5: ...one of up to the same number of sections on the boom and illustrated on the Operation screen Switches control individual boom sections On Flip the switch up Off Flip the switch down Master switch ope...

Page 6: ...sure gauge displays current pressure range compared with recommended pressure range Droplet size displays selected droplet size Boom sections displays configured boom sections Spray status displays ac...

Page 7: ...sing the Application rate section on the Information bar on the Operation screen Manual regulation mode will retain an established regulation valve setting regardless of speed The regulation valve set...

Page 8: ...ETERS Job parameters configures the target application rate settings and current nozzle Selections are also active on the Operation screen 1 From the Home screen press the SETTINGS button 2 Press Job...

Page 9: ...cts a regulation mode Calibrations establishes either manual automatic settings of the Implement speed sensor Flow sensor Liquid pressure sensor Fill flow sensor and Tank level sensor Alarms establish...

Page 10: ...les in the current section number Copy section sets all Number of nozzles counts to the same count for all boom sections based upon the current Section number Section width displays the width for the...

Page 11: ...tion of this guide 1 From the Home screen press the SETTINGS button 2 Press Machine 3 Press Calibrations 4 Select from Implement speed sensor establishes the wheel impulses over a specified distance F...

Page 12: ...re Alarms Nozzle preset Minimum tank content Fill valve No pressure calibration Minimum tank content Nozzle series Automatic filling Section number Maximum pressure Flow pressure cross check Nozzle ca...

Page 13: ...isplayed active on the Operation screen may be exported as a PDF report Job information includes Job number of information displayed Current date Applied area Volume of material applied Distance trave...

Page 14: ...ic calibration Flow sensor The Flow sensor establishes the impulses per litre Establish the value manually or automatically calibrate the value Calibration number enter the amount of impulses counted...

Page 15: ...d To cancel the calibration press Cancel RETURN arrow or the Home button Figure 21 Automatic calibration Liquid pressure sensor The liquid pressure sensor settings establish the maximum pressure limit...

Page 16: ...hen complete Master switch status Pressure adjustment Shows if the Master switch is off or on Press the UP DOWN arrows to increase decrease the pressure until reaching and maintaining the reference pr...

Page 17: ...flow meter is unknown or to make sure the value is correct Impulse count number of impulses calculated during automatic calibration Collected volume enter the collected volume Automatic calibration do...

Page 18: ...tion settings can be exported to a USB drive and recalled for future use NOTE Manual calibration is not available for any Tank level sensor calibrations 1 From the Home screen press the SETTINGS butto...

Page 19: ...screen The amount displayed is established in Settings OEM Tank setup Minimum tank content 1 Press Calibrate to record a new calibration value and finalise the calibration The low high graph should d...

Page 20: ...press RETURN arrow or press the Home button Figure 33 Tank level sensor Tank shape Import export Tank level sensor calibration settings can be exported to USB drive and recalled for future use NOTE T...

Page 21: ...displays current flow rate Flow pressure displays current flow pressure Speed displays vehicle speed Area applied displays applied area for the selected job number Job number displays the current job...

Page 22: ...ly for the selected number These settings will be the same for all active jobs Range is 0 to 6 554 litres hectare Select target application rate 1 Press the Application rate section 2 Select one 1 of...

Page 23: ...ent Increase decrease percentage 1 From the Operation screen press the OPTIONS tab to display the Operation menu 2 Press the Boost step percent increase decrease buttons 5 5 to adjust application rate...

Page 24: ...les Nozzle preset setup establishes up to five 5 sets of nozzle options setting the nozzle type capacity low high pressure limit reference flow and reference pressure For more information see Settings...

Page 25: ...ank sensor or Fill flow sensor is active Density type Density factor available when Density type is Fertiliser Desired content available when Tank sensor or Fill flow sensor is active Automatic fillin...

Page 26: ...ange are directly associated with the current droplet sizes The droplet size displays as one 1 of eight 8 classification categories Table 1 Droplet size chart Category Symbol Colour code Extremely fin...

Page 27: ...eck components and programming steps related to pressure Settings Machine Implement parameters Nozzle preset setup 2 15 Pressure too high Check components and programming steps related to pressure Set...

Page 28: ...ctive companies or organizations Limitation of Liability TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED NO COPYRIGHT LIABILITY OR PATENT IS A...

Reviews: