11
98-01467-EN R1
Radion 8140 automatic sprayer control
Flow sensor automatic calibration
1. Press
Calibrate
to enter automatic calibration mode.
2. Prepare to collect the ‘medium’ via the Flow sensor (minimum
100 litres).
3.
Make sure the controller is in manual mode and flow is not
regulated down.
4. Turn on the Master switch
to start flow and calibration.
◄Impulses counted display during the automatic calibration
5. Once at the minimum 100 litres has distributed, turn off
Master switch
to stop calibration.
6. Press the Collected volume value
.
7.
Enter the precise volume which passed through the flow sensor
during the calibration.
Once encoded, a new flow sensor calibration value is calculated.
To cancel the calibration, press
Cancel
, RETURN arrow or the
Home button
.
Figure 21: Automatic calibration
Liquid pressure sensor
The liquid pressure sensor settings establish the maximum pressure
limit and no pressure calibration for the liquid pressure sensor.
1.
From the Home screen, press the SETTINGS button
.
2. Press
Machine
.
3. Press
Calibrations
.
4. Press
Liquid pressure sensor
.
5. Calibrate each option in the following order:
No pressure
Maximum pressure
6. Press RETURN arrow to return to the Calibrations screen.
Figure 22: Liquid pressure sensor
No pressure
Liquid pressure sensor->No pressure establishes the calibration
while
NO
pressure is applied to the liquid pressure sensor.
1. Remove all pressure from the system.
2. Press
Calibrate
to record a new calibration value and finalise the
calibration.
NOTE: Manual calibration is not available.
Figure 23: Liquid pressure sensor->No pressure