13
98-01467-EN R1
Radion 8140 automatic sprayer control
Maximum pressure manual calibration
1.
Press the Maximum pressure value
.
2.
Enter the maximum allowed pressure limit for the liquid pressure
sensor.
Figure 26: Manual maximum pressure
Fill flow sensor
The Fill flow sensor establishes the impulses per litre. The Fill flow
value can be established manually or automatically calibrated.
►Calibration number – enter the amount of impulses counted
while running one (1) litre of water through the Fill flow
sensor. Use Automatic calibration to calculate the impulses
automatically. Manual calibration establishes the calibration
and limits based on user entered values.
►Automatic calibration – establishes the calibration if the
number of impulses per litre for the Fill flow meter is unknown,
or to make sure the value is correct.
►Impulse count – number of impulses calculated during
automatic calibration.
►Collected volume – enter the collected volume.
►Automatic calibration done – to complete the automatic
calibration, press “Done” when collected volume has been
entered.
Figure 27: Fill flow sensor
Fill flow sensor automatic calibration
1. Press
Calibrate
to enter automatic calibration mode.
2.
Prepare to collect the ‘medium’ via the Fill flow sensor (minimum
of 100 litres).
3. Turn on Master switch
to start flow.
4. Press START CALIBRATION button
.
◄Impulses counted display during automatic calibration
5. Once the desired amount has distributed, press the STOP
CALIBRATION button
.
6. Turn off the Master switch
.
7. Press the Collected volume value
.
8.
Enter the precise volume passed through the Fill flow sensor
during the calibration.
9. Press
Done
to complete the automatic calibration.
To cancel the calibration, press RETURN arrow
or the Home
button
.