15
98-01467-EN R1
Radion 8140 automatic sprayer control
Empty tank – Automatic calibration
Empty tank establishes the empty tank value.
IMPORTANT: The tank should be completely empty.
1. Press
Calibrate
to record a new calibration value and finalise the
calibration.
◄The low-high graph should be empty
Figure 30: Tank level sensor – Empty tank
Minimum tank level – Automatic calibration
Minimum tank level establishes the minimum level of water on the
tank sensor.
IMPORTANT: Make sure the tank is filled with the contents displayed
on the screen. The amount displayed is established in
Settings->OEM->Tank setup->Minimum tank content.
1. Press
Calibrate
to record a new calibration value and finalise the
calibration.
◄The low-high graph should display approximately 5% full
Figure 31: Tank level sensor – Minimum tank level
Maximum tank level – Automatic calibration
Maximum tank level establishes the maximum level of water on the
tank sensor.
IMPORTANT: Ensure the tank is filled with the contents displayed on
the screen. The amount displayed is established in Settings-
>OEM->Tank setup->Maximum tank content.
1. Press
Calibrate
to record a new calibration value and finalise the
calibration.
◄The low-high graph should display 100% full
Figure 32: Tank level sensor – Maximum tank level