Radion 8140 automatic sprayer control
ALARM CONFIGURATIONS
Code
Message / condition
Possible solution
Console path
1
No flow impulses
Check flow sensor from test menu. Check components and
programming steps related to flow.
Settings->Diagnostics->Test inputs (1)->
Flow sensor
2
Low liquid pressure
Check flow sensor from test menu. Check components and
programming steps related to flow.
Settings->Machine->Implement parameters->
Nozzle preset setup (2) or Settings->Machine->
Calibrations or Settings->Diagnostics->Test inputs
(2)->Liquid pressure sensor
4
Calibration error
Check components and programming steps related to
implement or process registering a calibration error.
Settings->Machine->Calibrations - check sensors
5
Density not equal to water
(1 kg/l or 8.34 lb/gal)
Select Water for tank contents or change fertiliser density No..
Check components and programming steps related to content.
Operation->Filling (1) or Settings->Machine->
Filling (1)
6
Below minimum speed
Increase speed. Check components and programming steps
related to speed.
Settings->Machine->Operation or Settings->
Machine-> Calibrations->Implement speed sensor
7
Pressure based
Check components and programming steps related to
implement or process registering a pressure error.
Settings->Diagnostics->Test inputs or Settings->
Machine->Implement parameters->Nozzle preset
setup (2)
8
Low flow
Increase speed. Check or clean nozzles. Check components
and programming steps related to flow.
Settings->Diagnostics->Test inputs or Settings->
Machine->Implement parameters->Nozzle preset
setup (2)
9
Tank almost empty
Refill tank. Check all components and programming steps
related to contents.
Operations->Tank->Filling (1) or Settings->
Machine-> filling (1) and (2) or Settings->
Machine-> Alarms-> Minimum tank contents
10
Target rate impossible to reach
Select a new target rate. Use larger nozzles. Check
components and programming steps related to rates.
Operation->Target rates or Settings->Job
parameters
11
Actual rate too high
Select a lower target rate. Check components and
programming steps related to rates.
Operation->Target rates or Settings->Job
parameters
12
Minimum regulation pressure
Check components and programming steps related to
pressure.
Settings->Machine->Implement parameters->
Regulation parameters
13
Maximum regulation pressure
Check components and programming steps related to
pressure.
Settings->Machine->Implement parameters->
Regulation parameters
14
Pressure too low
Check components and programming steps related to
pressure.
Settings->Machine->Implement parameters->
Nozzle preset setup (2)
15
Pressure too high
Check components and programming steps related to
pressure.
Settings->Machine->Implement parameters->
Nozzle preset setup (2)
16
Pressure/flow check
Check components and programming steps related to flow.
Settings->Diagnostics->Test inputs or Settings->
Machine->Calibrations
19
Liquid pressure too low
Check flow sensor from test menu. Check components and
programming steps related to pressure.
Settings->Machine->Implement parameters->
Nozzle preset setup (2) or Settings->Machine->
Calibrations or Settings->Diagnostics->Test inputs
(2)->Liquid pressure sensor
20
Liquid pressure too high
Check flow sensor from test menu. Check components and
programming steps related to pressure.
Settings->Machine->Implement parameters->
Nozzle preset setup (2) or Settings->Machine->
Calibrations
21
No speed signal
Check components and programming steps related to speed.
Settings->Machine->Calibrations->Implement
speed sensor
31
Work not possible
34
Save error
Insert or reset a USB device if saving to a USB port.
36
CAN speed missing
Check GNSS source for power/satellite reception. If no
GNSS source, change speed source. Check components and
programming steps related to speed.
Settings->Machine->Operation->Speed source
45
BoomPilot unit not responding
Check BoomPilot for power. Test BoomPilot under test menu.
Settings->Diagnostics->Test BoomPilot
46
BoomPilot unit in manual mode
Current operation mode is different than standard operation. If
this is undesired, change mode to automatic under test menu.
Settings->Diagnostics->Test BoomPilot
47
Not all sections on
Current operation mode is different than standard operation. If
this is undesired, check section switches are flipped up (ON).
Check sections under test menus. Configure sections. Check
components and programming steps related to power.
Settings->Diagnostics->Test outputs (2) or
Settings-> Diagnostics->Test inputs (3)->Section
switches or Settings->Machine->Implement
parameters->Section configuration
49
Section output failure
Check components and programming steps related to sections. Settings->Diagnostics->Test outputs (2)
50
Master output failure
Check Master switch if flipped up (ON). Check all components
and programming steps related to Master switch.
Settings->Diagnostics->Test inputs (3)->Master
switch
51
Fill valve output failure
Check fill valve under test menus. Check components and
programming steps related to fill valve.
Settings->Diagnostics->Test outputs (2)->Fill valve
52
Low supply voltage
Check voltage supply under Diagnostics.
Settings->Diagnostics->Supply voltage