SENSOR CALIBRATIONS
Implement speed sensor
The Implement speed sensor establishes the wheel impulses over
a specified distance. Establish the value manually or automatically
calibrate the value.
►Calibration number –
◄Automatic calibration will determine the number of impulses
counted while driving 100 metres and convert the calibration
number to the correct units.
◄Manual calibration, enter the calibration number in impulses
per 100 meters
►Automatic calibration – establishes the impulses using the
automatic calibration function.
Figure 19: Implement speed sensor
Implement speed sensor automatic calibration
1. Press
Calibrate
to start an automatic sensor calibration.
2. Drive a distance of 100 metres.
3. Press
Done
when complete.
To cancel the calibration, press
Cancel
, RETURN arrow or the
Home button
.
The counted wheel impulses will be displayed during the automatic
calibration.
Flow sensor
The Flow sensor establishes the impulses per litre. Establish the
value manually or automatically calibrate the value.
►Calibration number – enter the amount of impulses counted
while running 1 litre of water through the flow sensor. Use
Automatic calibration to calculate impulses automatically.
Manual calibration establishes the calibration and limits based
on user-entered values.
►Low flow limit – enter the flow sensors low limit value.
►High flow limit – enter the flow sensors high limit value.
►Automatic calibration – establishes the calibration and limits if
the number of impulses per litre for the flow meter is unknown
or to make sure the value is correct.
►Impulse count – shows the number of impulses during
calibration. Minimum of 10 impulses needed to do a
calibration.
►Collected volume – enter the volume passed through the
flow sensor during the calibration. Once encoded, a new flow
sensor calibration value is calculated.
►Master switch status / Cancel – shows if the Master switch is
off or on .
Press the
Cancel
to cancel the calibration and return to the
Flow sensor screen.
Figure 20: Flow sensor